Variometer — Manual
3. Maintenance & Repair
2.2.4
Power -
POWER
Connect supplied connector at the back of Indu Variometer. The
connector has a notch on one side, which protects from wrong orien-
tation.
Connect blue lead to negative (ground) terminal and red lead to
positive (+12-24 V) terminal.
The cable side of power connector consists of the following parts:
plastic part with a hook . . . W¨
urth Elektronik, PN 649 002 113
322,
two female crimp terminals . . . W¨
urth Elektronik, PN 649 006
137 22,
0.75 mm
2
(about AWG 18) red and blue leads.
The terminals have finitive number of mating cycles. They belong to
the 25 mating cycles quality class.
The power input shall be routed trough a suitable circuit breaker.
3
Maintenance & Repair
No special maintenance is required. A static leak test should be
performed annually and calibration check biannually. In the case of
small deviation, use the procedure described in section
??
.
The instrument has no serviceable parts inside. In the case of mal-
function, it must be sent to factory for a repair.
10
©
Kanardia
2015 - 2020