Emsis — Manual
7.2
Hardware Tank
3. Once the correct shape is selected, press
close
to save the
selection.
4. Select the
Tank:T1 min/max
from the menu. Figure 37 shows
an example.
Figure 37:
Window for setting the tank minimum and maximum val-
ues. Your values will be different.
Here you have two options. The first option is to drain the tank,
set the sensor minimum value. Then fill up the value and set
sensor maximal value. The second option is to manually enter
some known min and max values from previous calibrations.
Working with fuel:
Make sure that the tank of the aircraft
is empty and the fuel level sensor is connected to Daqu
unit. In the
Sens
row you can observe the sensor value.
When tank is empty, select the
Min
item and press and
hold the
OK
button to copy the sensor value into min.
Fill the tank, select the
Max
item and press and hold the
OK
button to copy the sensor value into max. Then close
all the windows. This completes the tank calibration.
Entering values:
Select the
Min
item and press the
OK
but-
ton. Enter the known value that sensor shows when tank
is empty. Then select the
Max
item and press
OK
. Enter
the known value that sensor shows when tank is full. Close
all the windows. This completes the tank calibration.
68
©
Kanardia
2021
Содержание EMSIS
Страница 1: ...EMSIS Installation and User Manual Kanardia d o o November 2021 Manual Revision 3 1 ...
Страница 2: ......
Страница 5: ...Emsis Manual 5 Kanardia 2021 ...