ULTRAFLOW® 54 (H)/(J)
Kamstrup A/S ∙ Technical Description ∙ 5512‐1554_J1_GB _04.2018
9
2.3
Flow data
Nom. flow q
p
Nom. diameter Meter factor
1)
Dynamic range
Flow@125 Hz
2)
p@q
p
Min. cutoff
[m³/h]
[mm]
[imp/l]
q
p
:q
i
q
s
:q
p
[m³/h]
[bar]
[l/h]
0.6
DN15/DN20
300
100:1
2:1
1.5
0.03
2
1.5
DN15/DN20
100
100:1
2:1
4.5
0.09
3
2.5
DN20
60
100:1
2:1
7.5
0.09
5
3.5
DN25
50
100:1
2:1
9
0.07
7
6
DN25
3)
25
100:1
2:1
18
0.20
12
6
DN25/DN32
25
100:1
2:1
18
0.06
12
10
DN40
15
100:1
2:1
30
0.06
20
1)
The meter factor appears from the type label.
2)
Saturation flow 125 Hz. Max. pulse frequency is maintained at higher flow.
3)
Types 65-5-CHJ6-XXX and 65-5-CHJ7-XXX.
Table 1. Flow data.
2.4
Materials
Wetted parts, ULTRAFLOW
®
54 (H)/(J)
Housing, coupling DZR brass (dezincification resistant brass), CW602N
Transducer
Stainless steel, W. no. 1.4401
Gaskets
EPDM
Reflectors
Thermoplastic, PES 30 % GF and stainless steel, W. no. 1.4301/
Stainless steel, W. no. 1.4301 (q
p
3.5 m
3
/h)
Measuring tube
Thermoplastic, PES (q
p
0.6…2.5 m
3
/h)/
PES 30% GF (q
p
≥
3.5 m
3
/h)
Electronics box, ULTRAFLOW
®
54 (H)/(J)
Base
Thermoplastic, PES 30 % GF (q
p
0.6…2.5 m
3
/h)/
PC 10% GF (q
p
≥
3.5 m
3
/h)
Cover
Thermoplastic, PC 10 % GF (q
p
0.6…2.5 m
3
/h)/
PC 20% GF (q
p
≥
3.5 m
3
/h)
Housing, Pulse Transmitter/Pulse Divider
Base, cover
Thermoplastic, PC 10 % GF
Signal cable
Silicone cable (3 x 0.5 mm
2
)
Mains supply cable 24/230 VAC
(optional when selecting mains supplied Pulse Transmitter/Pulse Divider)
Cable with PVC-mantle (2 x 0.75 mm²)
Housing, Cable Extender Box
Base, cover
ABS
Содержание ULTRAFLOW 54 Series
Страница 2: ...ULTRAFLOW 54 H J 2 Kamstrup A S Technical Description 5512 1554_J1_GB_04 2018...
Страница 6: ...ULTRAFLOW 54 H J 6 Kamstrup A S Technical Description 5512 1554_J1_GB_04 2018...
Страница 91: ...ULTRAFLOW 54 H J Kamstrup A S Technical Description 5512 1554_J1_GB _04 2018 91...
Страница 92: ...ULTRAFLOW 54 H J 92 Kamstrup A S Technical Description 5512 1554_J1_GB_04 2018...