ULTRAFLOW® 54 (H)/(J)
Kamstrup A/S ∙ Technical Description ∙ 5512‐1554_J1_GB _04.2018
83
q
p
CCC
[m³/h]
[imp/l]
[l/imp] Divider
DD
[ms]
[ms] (E=4) [ms] (E=5) [ms] (E=6)
40
158
5
3.9
-
-
-
Default
40
10
50
34
-
20
50
-
40
25
125
64
-
-
-
100
40
100
500
35
-
-
-
100
40
250
1250
65
-
-
-
100
60
170
2.5
3.9
-
-
-
Default
60
10
25
34
-
20
50
-
60
25
62.5
64
-
-
-
100
60
100
250
35
-
-
-
100
60
250
625
65
-
-
-
100
100
180
1.5
3.9
-
-
-
Default
100
10
15
34
-
20
50
-
100
100
150
35
-
-
-
100
100
250
375
65
-
-
-
100
Meter factor
Pulse duration
Table 29. Configuration variants of meter factor (DD) and pulse duration (E)
for Pulse Divider for ULTRAFLOW
®
54 and 34, qp 40…100.
Based on a q
p
-value one of the meter factor options for the Pulse Divider is selected from
Table 27
or
Table 29
. The
pulse duration options appear from the same line as the selected meter factor.
Example: For ULTRAFLOW
®
54 with q
p
40 m
3
/h (5 imp/l, CCC=158) a pulse figure of 10 l/pulse (DD=34) for the Pulse
Divider is required. Based on this pulse figure you have the option of pulse durations 20 (E=4) or 50 (E=5)
milliseconds.
For older types of ULTRAFLOW
®
(e.g. ULTRAFLOW
®
type 65) which do not have the same direct and unique
connection between q
p
and meter factor (CCC), correct configuration can be ensured by starting from the meter
factor of the flow sensor [imp/l].
Default values in
Table 27
and
Table 29
indicate meter factors and pulse durations of ULTRAFLOW
®
54 and 34.
Содержание ULTRAFLOW 54 Series
Страница 2: ...ULTRAFLOW 54 H J 2 Kamstrup A S Technical Description 5512 1554_J1_GB_04 2018...
Страница 6: ...ULTRAFLOW 54 H J 6 Kamstrup A S Technical Description 5512 1554_J1_GB_04 2018...
Страница 91: ...ULTRAFLOW 54 H J Kamstrup A S Technical Description 5512 1554_J1_GB _04 2018 91...
Страница 92: ...ULTRAFLOW 54 H J 92 Kamstrup A S Technical Description 5512 1554_J1_GB_04 2018...