background image

Installation and operation guide

Kamstrup A/S • 55122428_A3_GB_04.2019

4

Contents

1  Product introduction 

 

 

5

1.1  System overview 

5

1.2  READy Mini Concentrator overview 

6

1.3  Data security 

6

1.4  Data transmission 

6

1.5  Data persistence 

6

2  Before you begin 

 

 

7

2.1 Precautions 

7

2.2  Register your device 

8

2.3  SIM card and data subscription 

9

2.3.1 Configuration 

 

 

9

2.3.2 Data subscription 

 

 

9

2.3.3 Disposal or decommissioning 

 

 

9

3  Installation and configuration 

 

 

9

3.1  Installation preconditions 

9

3.2  Installation locations 

10

3.2.1  Installation for priority data 

 

 

10

3.2.2 Installation for hourly data 

 

 

10

3.3  Installation of READy Mini Concentrator 

10

3.3.1 Preconditions 

 

 

10

3.3.2 Installation steps 

 

 

11

3.4  Configuration of READy Mini Concentrator 

11

3.4.1   Configuration within 20 m of the meters that you intend to read  

 

12

3.4.1.1  For Ethernet and GSM 

 

 

12

3.4.1.2 For Wi-Fi installation 

 

 

12

3.4.2 Configuration more than 20 m from the meters that you intend to read   

 

12

4 Operation 

 

 

16

4.1  Normal operation 

16

4.2 Decommissioning 

16

4.3  Redeployment and configurations 

16

5  Maintenance and support 

 

 

16

5.1 Transport 

16

5.2  Firmware updates 

16

5.3  Kamstrup support 

16

6 Storage 

 

 

17

7 Disposal 

   

17

7.1  Disposal by Kamstrup A/S 

17

7.2  The customer sends for disposal 

17

7.3  Disposal by the customer himself 

17

8  Troubleshooting and FAQ 

 

 

18

8.1 Installation 

18

8.2 Operation 

19

8.3 Maintenance 

19

9 Warranty 

 

 

20

10 Markings 

 

 

20

Содержание READy Mini Concentrator

Страница 1: ...Kamstrup A S 55122428_A3_GB_04 2019 READy Mini Concentrator Warning Read instructions before installation Installation and operation guide...

Страница 2: ...or trademark of Kamstrup to any other party This disclaimer includes but is not limited to implied warranties of merchantability fitness for any particular purpose and non infringement Information in...

Страница 3: ...oduct may only be installed by trained personnel Do not remove the product labels as they contain important information Read the Kamstrup Wireless M Bus radio network installation guide before install...

Страница 4: ...tallation of READy Mini Concentrator 10 3 3 1 Preconditions 10 3 3 2 Installation steps 11 3 4 Configuration of READy Mini Concentrator 11 3 4 1 Configuration within 20 m of the meters that you intend...

Страница 5: ...m smart energy and water meters or sensors and transmits the data via Ethernet Wi Fi cellular 2G connection to READy Manager READy Mini Concentrator has a reach of approximately 40 60 m depending on t...

Страница 6: ...3 Data security READy Mini Concentrator is part of the complete end to end data encryption in the READy Suite Data is AES 128 bit end to end encrypted from the meter to READy Manager and READy Mini C...

Страница 7: ...accountable for any malfunctions or misuse of the product The product may only be installed by trained personnel Do not remove the product labels as they contain important information Read the Kamstru...

Страница 8: ...EADy Mini Concentrator in your My Kamstrup account in order to get the encryption key Please follow these steps 1 Log in to My Kamstrup and go to Encryption Key Service 2 Go to Manage devices and Regi...

Страница 9: ...p to 55 MB and is remotely initiated by Kamstrup Normal Priority data 1 meter 0 25 MB month 8 MB month 10 meters 2 MB month 80 MB month 25 meters 5 MB month 200 MB month 2 3 3 Disposal or decommission...

Страница 10: ...1 Installation for priority data To maintain a stable priority data reception from the meter to READy Mini Concentrator install READy Mini Concentrator with line of sight to the meter no more than 20...

Страница 11: ...before powering on the product 4 Insert the power adapter in a wall socket and READy Mini Concentrator 5 The installation is complete Follow the configuration steps to ensure that READy Mini Concentra...

Страница 12: ...en trator on check kamstrup com Note the time of the reading Concentrator can be read Last read 12 07 2018 02 00 See connected devices Test the new device 3 4 1 2 For Wi Fi installation See the config...

Страница 13: ...will present itself as READyMiniConc_SERIAL where SERIAL is the serial number of your device The Wi Fi SSID posted by READy Mini Concentrator is active for 15 minutes If the Wi Fi timer runs out press...

Страница 14: ...onnect For Wi Fi Choose the Wi Fi that you want to connect to and enter the associated Wi Fi password For Ethernet GSM READy Mini Concentrator recognizes the connection and shows that it is connected...

Страница 15: ...2019 15 9 READy Mini Concentrator connects to READy Manager and the configuration is now complete 10 Ensure that you can see READy Mini Concentrator on check kamstrup com Concentrator can be read Last...

Страница 16: ...ioned for disposal see section 7 Disposal If READy Mini Concentrator is to be decommissioned simply unplug the power supply READy Mini Concentrator will immediately stop sending data to READy Manager...

Страница 17: ...up A S Kamstrup A S accepts READy Mini Concentrator by the end of operation for environmentally correct disposal according to previous agreement The disposal is free of charge to the customer except f...

Страница 18: ...sure that the meter sensor radio is on Depending on the meter configuration it can take up to 96 seconds to receive a data package Move closer to the meter that you want to receive data from dependin...

Страница 19: ...centrator A Yes Simply go through the web interface configuration again If changing from a GSM connection to either Wi Fi or Ethernet remember to disconnect the SIM card Q Do I haveto pairthe devicest...

Страница 20: ...covered by the standard warranty the product is repaired or replaced free of charge The warranty also covers all product components including consumables For extended warranty please contact Kamstrup...

Отзывы: