background image

Installation and operation guide

Kamstrup A/S • 55122428_A3_GB_04.2019

2

Disclaimer

All information provided in this document is copyright of Kamstrup. Licence is granted 
to the user to freely use and distribute the information in complete and unaltered form, 
provided that the purpose is to use or evaluate Kamstrup products. Distribution rights do 
not include public posting or mirroring on Internet websites. Only a link to the Kamstrup 
website can be provided on such public websites.
Kamstrup shall in no event be liable to any party for direct, indirect, special, general, 
incidental, or consequential damages arising from the use of this information or any 
derivative works thereof. The information is provided on an as-is basis, and thus comes 
with absolutely no warranty, either express or implied. No right or licence is granted under 
any intellectual property right, hereunder copyright, patent or trademark, of Kamstrup 
to any other party. This disclaimer includes, but is not limited to, implied warranties of 
merchantability, fitness for any particular purpose, and non-infringement. 
Information in this document is subject to change without notice and should not be 
construed as a commitment by Kamstrup. While the information contained herein is 
believed to be accurate, Kamstrup assumes no responsibility for any errors and/or 
omissions that may appear in this document.

Copyright Information

Copyright ® Kamstrup A/S
Industrivej 28 
Stilling
DK-8660 Skanderborg, Denmark

All Rights Reserved

The graphics and content in this document are the copyrighted work of Kamstrup and 
contain proprietary trademarks and trade names of Kamstrup. 

Third parties

This document may contain links to other parties. Kamstrup makes no warranty or 
representation regarding any linked information appearing therein. Such links do not 
constitute an endorsement by Kamstrup of any such information and are provided only 
as a convenience. Kamstrup is not responsible for the content or links displayed by third 
parties.

Содержание READy Mini Concentrator

Страница 1: ...Kamstrup A S 55122428_A3_GB_04 2019 READy Mini Concentrator Warning Read instructions before installation Installation and operation guide...

Страница 2: ...or trademark of Kamstrup to any other party This disclaimer includes but is not limited to implied warranties of merchantability fitness for any particular purpose and non infringement Information in...

Страница 3: ...oduct may only be installed by trained personnel Do not remove the product labels as they contain important information Read the Kamstrup Wireless M Bus radio network installation guide before install...

Страница 4: ...tallation of READy Mini Concentrator 10 3 3 1 Preconditions 10 3 3 2 Installation steps 11 3 4 Configuration of READy Mini Concentrator 11 3 4 1 Configuration within 20 m of the meters that you intend...

Страница 5: ...m smart energy and water meters or sensors and transmits the data via Ethernet Wi Fi cellular 2G connection to READy Manager READy Mini Concentrator has a reach of approximately 40 60 m depending on t...

Страница 6: ...3 Data security READy Mini Concentrator is part of the complete end to end data encryption in the READy Suite Data is AES 128 bit end to end encrypted from the meter to READy Manager and READy Mini C...

Страница 7: ...accountable for any malfunctions or misuse of the product The product may only be installed by trained personnel Do not remove the product labels as they contain important information Read the Kamstru...

Страница 8: ...EADy Mini Concentrator in your My Kamstrup account in order to get the encryption key Please follow these steps 1 Log in to My Kamstrup and go to Encryption Key Service 2 Go to Manage devices and Regi...

Страница 9: ...p to 55 MB and is remotely initiated by Kamstrup Normal Priority data 1 meter 0 25 MB month 8 MB month 10 meters 2 MB month 80 MB month 25 meters 5 MB month 200 MB month 2 3 3 Disposal or decommission...

Страница 10: ...1 Installation for priority data To maintain a stable priority data reception from the meter to READy Mini Concentrator install READy Mini Concentrator with line of sight to the meter no more than 20...

Страница 11: ...before powering on the product 4 Insert the power adapter in a wall socket and READy Mini Concentrator 5 The installation is complete Follow the configuration steps to ensure that READy Mini Concentra...

Страница 12: ...en trator on check kamstrup com Note the time of the reading Concentrator can be read Last read 12 07 2018 02 00 See connected devices Test the new device 3 4 1 2 For Wi Fi installation See the config...

Страница 13: ...will present itself as READyMiniConc_SERIAL where SERIAL is the serial number of your device The Wi Fi SSID posted by READy Mini Concentrator is active for 15 minutes If the Wi Fi timer runs out press...

Страница 14: ...onnect For Wi Fi Choose the Wi Fi that you want to connect to and enter the associated Wi Fi password For Ethernet GSM READy Mini Concentrator recognizes the connection and shows that it is connected...

Страница 15: ...2019 15 9 READy Mini Concentrator connects to READy Manager and the configuration is now complete 10 Ensure that you can see READy Mini Concentrator on check kamstrup com Concentrator can be read Last...

Страница 16: ...ioned for disposal see section 7 Disposal If READy Mini Concentrator is to be decommissioned simply unplug the power supply READy Mini Concentrator will immediately stop sending data to READy Manager...

Страница 17: ...up A S Kamstrup A S accepts READy Mini Concentrator by the end of operation for environmentally correct disposal according to previous agreement The disposal is free of charge to the customer except f...

Страница 18: ...sure that the meter sensor radio is on Depending on the meter configuration it can take up to 96 seconds to receive a data package Move closer to the meter that you want to receive data from dependin...

Страница 19: ...centrator A Yes Simply go through the web interface configuration again If changing from a GSM connection to either Wi Fi or Ethernet remember to disconnect the SIM card Q Do I haveto pairthe devicest...

Страница 20: ...covered by the standard warranty the product is repaired or replaced free of charge The warranty also covers all product components including consumables For extended warranty please contact Kamstrup...

Отзывы: