TECHNICAL DESCRIPTION
MULTICAL
®
61
5512-622 GB/01.2011/Rev. E1
30
8.5
Data loggers
MULTICAL
®
61 includes a permanent memory (EEPROM), in which the values of various data loggers are saved. The
meter includes the following data loggers:
Data logging interval
Data logging depth
Logged value
Yearly logger
15 years
Counter register
•
Monthly logger
36 months
Counter register
•
Daily logger
460 days and nights
Consumption (increase)/day
♦
Hourly logger (Top module)
1392 hours
Consumption
(increase)/hour
♦
Info logger
50 Events (36 events can be displayed)
Info code and date
The loggers are static and the register types can therefore not be changed, the same applies to the logging
intervals. When the EEPROM is full the oldest data will be overwritten.
8.5.1
Yearly, monthly, daily and hourly loggers
The following registers are logged every year and every month on target date as counter values. Furthermore, the
day and hour increases are logged at midnight.
Register type
Description
Yearly
logger
Monthly
logger
Daily
logger
Hourly
logger
Date (YY.MM.DD)
Year, month and day of logging time
•
•
♦
♦
V1
Volume register for Volume 1
•
•
♦
♦
VA
Extra water or electricity meter connected to
Input A
•
•
♦
♦
VB
Extra water or electricity meter connected to
Input B
•
•
♦
♦
INFO
Information code
•
•
♦
♦
DATE FOR MAX. FLOW V1
Date stamp for max. flow during period
•
•
-
-
MAX. FLOW V1
Value of max. flow during period
•
•
-
-
DATE FOR MIN. FLOW V1
Date stamp for min. flow during period
•
•
-
-
MIN. FLOW V1
Value of min. flow during period
•
•
-
-
8.5.2
Info logger
Every time the information code changes, date and info codes are logged. Thus, it is possible to data read the
latest 50 changes of the information code as well as the date the change was made.
Register type
Description
Date (YY.MM.DD)
Logging time, year, month and day
info
Information code on above date
When the info logger is read from the display, only the latest 36 changes including dates can be read. All 50
changes can be read via METERTOOL.