Type 67-09: RTC +
D
volume calculation and hourly
data logger
This top module calculates the difference between
forward and return volume, whereby an expression
of the tapped energy in open systems is obtained.
Differential volume dV=V1-V2.
The module also comprises a hourly data logger.
Terminal screws are not used in this module.
Type 67-0A: RTC + 2 pulse outputs for CE and
CV + hourly data scheduler
The top module has the same functions as the 67-
08 top module and furthermore the module is able
to simulate a cold water temperature according to
a programmed scheduler, where the programmed
temperature for T2, T3 or T4 can be programmed
with up to 12 individual dates/temperatures per
year.
This function is available for T3 and T4 of all
MC601 models, but the scheduler function of T2 is
restricted for the 67-E only.
Type 67-0B: RTC + 2 pulse outputs for CE and
CV + prog. data logger
The RTC and pulse output functions of this top
module are identical with the functions described
under top module 67-08.
The top module is prepared for use in a Kamstrup
radio network together with the Radio Router
base module 6700210003xx, read data being
transferred to the system software via network unit
RF Concentrator.