Allowed operation conditions/measuring ranges
Complete cooling meter with national Danish cooling approval
(TS 27.02 005):
Calculator
q
: 2 °C…50 °C
DΘ
: 3K…40K
Flow meter (medium temperature)
q
: 2 °C…50 °C
Combined heat/cooling meter with national Danish cooling and MID approval
(TS 27.02 005 and DK-0200-MI004-013):
Calculator
q
: 2 °C…160 °C
DΘ
: 3K…150K
Flow meter (medium temperature)
q
: 2 °C…130 °C
Mechanical environment
M1 (fixed installation with minimum vibration).
Electromagnetic environment
E1 (housing/light industry). The meter’s control cables must be drawn at
min. 25 cm distance to other installations.
Climatic environment
Must be installed in environments with non-condensing humidity as well
as in closed locations (indoors). The ambient temperature must be within
5…55 °C.
Maintenance and repair
The energy supplier can replace communication module, battery and
temperature sensors. Flow sensor and calculator must not be separat-ed.
Other repairs require subsequent reverification in an accredited laboratory.
MULTICAL® 402-T requires connection of temperature sensors type Pt500.
Battery for replacement
Kamstrup type 402-000-2000-000 (D-cell) or 402-000-1000-000
(2 x AA-cells).