TECHNICAL DESCRIPTION MULTICAL® 21 & flowIQ® 2101 /..02 /..03
20
Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016
4
Type overview
The type number of the meter can not be changed after factory programming.
The country code, also used for:
Language and approval on type label
Temperature class of water meter (T30, T50 or T70)
4.1
Type overview – MULTICAL® 21 / flowIQ® 2101
Type 021-
0
Communication
Wireless M-Bus, 868 MHz, mode C1 – ver. 2
46
Wireless M-Bus, 868 MHz, mode T1 – OMS – ver. 2
47
Supply
16 years’ battery life, C-cell
C
Meter size
Q3 [m³/h]
Connection
Length [mm]
Dynamic range
1.6
G¾B (R½)
110
1:160
A
1.6
G¾B (R½)
110
1:100
B
2.5
G¾B (R½)
110
1:250
D
2.5
G¾B (R½)
110
1:100
C
2.5
G1B (R¾)
105
1:250
G
2.5
G1B (R¾)
105
1:100
F
2.5
G1B (R¾)
130
1:250
H
2,5
G1B (R¾)
130
1:100
J
4.0
G1B (R¾)
130
1:250
L
4,0
G1B (R¾)
130
1:100
M
2.5
G1B (R¾)
190
1:250
E
2,5
G1B (R¾)
190
1:100
K
4.0
G1B (R¾)
190
1:250
N
4.0
G1B (R¾)
190
1:100
P
Meter type
Hot water meter, T70, T30/70 (OIML R49)
7
Cold water meter, T30 or T50 (MID)
8
Country code (language on label etc.) Numbers or letters
XX