TECHNICAL DESCRIPTION MULTICAL® 21 & flowIQ® 2101 /..02 /..03
14
Kamstrup A/S •Technical Description • 5512-897_J1_GB • 06.2016
3.5.3
flowIQ® 2102 – Australia
Nom.
flow
Q
3
Min.
flow
Q
1
Max
flow
Q
4
Dynamic
range
Q
3
/Q
1
Min.
cut-
off
Max
cut-off
**)
Pressure
loss
p at Q
3
Connection
on meter
Length
Non-
return
valve
Strainer
mounted
Type number
m
3
/h
l/h
m
3
/h
l/h
m
3
/h
bar
mm
02A-YY-C0D-XXX
2.5
10
3.1
250
2
4.6
0.55
G¾B
110
Yes
Yes
02A-YY-C0L-XXX
4.0
16
5.0
250
3.2
8.5
0.38
G1B
130
Yes
Yes
YY =
80 = 923 MHz
XXX = Country Code/time zone
XAC = Australia Central
XAE = Australia Eastern
XAW = Australia Western
3.5.4
flowIQ® 2102 – Chile
Type number
Nom.
flow
Q
3
Min.
flow
Q
1
Max
flow
Q
4
Dynamic
range
Q
3
/Q
1
Min.
cut-
off
Max
cut-off
**)
Pressure
loss
p at Q
3
Connection
on meter
Length
Non-
return
valve
Strainer
mounted
m
3
/h
l/h
m
3
/h
l/h
m
3
/h
bar
mm
02A-36-C0D-8XX
2.5
10
3.1
250
2
4.6
0.55
G¾B
110
Yes
Yes
02A-36-C0L-8XX
4.0
16
5.0
250
3.2
8.5
0.38
G1B
130
Yes
Yes
YY = 36 = 915 MHz
XX =
Country Code