TECHNICAL DESCRIPTION flowIQ® 3100
50
Kamstrup
A/S • Technical Description •
5512-1242_N
1_GB •
10.2019
17.3
Optional register in data logger
Some of the data sent via the radio signal is optional. It is possible to select one of the data packages with content
as listet in section
or
The choices are determined by means of the selected R-value when ordering a water.
See description of Wireless M-Bus signal in section
17.4
Loggers
Configuration options as shown below:
Function
DataTool
(licensed)
METERTOOL
LogView
LabTool
(licensed)
Logger depth settings
✓
RF enable/disable
✓
Communication module ID change
✓
Data packet settings
✓
✓
Logger readout
✓
17.5
DataTool
With DataTool the water supply company has the option to change various settings in the water meters that are
connected to the customer number. After Data Tool has been installed on the computer, the supply company
can choose between different modules and communication standards.
If the meter for example is purchased with module 40, it can be reconfigured to match one of the other
modules. In addition to this, the radio can be turned off when needed. Already during the ordering process the
desired setting is taken into account. DataTool can be obtained from Kamstrup by sending an e-mail to
Module
Battery lifetime
16 years
12 years
10 years
40
✓
41
✓
42
✓
46**
✓
48
✓
Transmission intervals:
Fixed Network:
96 seconds
Drive-by solution:
16 seconds
*
Detail information about modules and battery lifetime
–
see document:
**
Module 46 is only for meter size DN100
With a lic
ensed configuration tool, ‘DataTool’, you can re
-configure the desired parameters (modules and data
packets) not available for METERTOOL etc. via optical eye.