TECHNICAL DESCRIPTION flowIQ® 3100
22
Kamstrup
A/S • Technical Description •
5512-1242_N
1_GB •
10.2019
8
Optional data packages
–
Sigfox installations
A part of the data transmitted through the Sigfox radio signal is optional. It is also possible to choose between the
different data so it changes from one data package to another. The target volume is mandatory for each
transmission, but transmission 1 can have information on max flow, whereas transmission 2 can have information
on min flow. This is called ‘Sigfox sequence’.
This is called ‘Sigfox sequence’.
Module
Battery life
16 years (< 30 °C)
Transmission interval
11
✓
Daily R=0 or R=1
13
✓
Daily sequence
97
✓
No transmission
–
radio disabled
Info codes are pushed one time, as soon as they occur. If the info code disappears and appears once again, a new
info code is pushed. The planned transmission will always hold information on active info codes.
9
Data Packages in Wireless M-Bus modules
Some of the data transmitted through the Wireless M-Bus radio signal are optional. It is possible to choose
between different protocols (C1, T1), and various reading intervals, by choosing a specific module.
For each module there is an option of choosing between up to 10 different data packages.
You must choose one data package.
Choise of datapackages
–