Maintenance

Filter maintenance KA-520 L: 

Take appropriate hygiene precautions to protect against 

harmful influences when changing the

 

filter:

Turn off the air purifier 5 hours before maintenance, so that the viruses contained in the filter
can die off!
Wear full protective clothing (long sleeves, long trousers, gloves, respiratory mask min. pro-
tective class FFP2, protective goggles)!

H14 particulate filter

Replace the H14 particulate filter at least every 6 months. Replace the filter immediately if the
indicator light below the suction grille lights up yellow before the specified time period!

Filter warning light

Place used filters in a plastic bag, then seal and dispose of the bag.

ISO Coarse pre-filter

Carefully vacuum the ISO Coarse pre-filter once a week or replace it if it becomes too dirty or
damaged.

Order replacement filters here:

Filter maintenance KA-520

 XL + XXL

Take appropriate hygiene precautions to protect against harmful influences when changing the

 

filter:

Turn off the air purifier 5 hours before maintenance, so that the viruses contained in the filter
can die off!
Wear full protective clothing (long sleeves, long trousers, gloves, respiratory mask min. pro-
tective class FFP2, protective goggles)!

H14 particulate filter

Replace the H14 particulate filter at least every 6 months. Re-order the filter (see QR code) if the
filter status light flashes (remaining operating time 50 hours). Replace the filter immediately if
the filter status light lights up permanently yellow before the specified time period! After repla-
cing the filter, reset the filter as stated on the adhesive sticker on the rear. The unit can only be
operated at operating stage II while the filter warning signal is on.

Filter warning light

Place used filters in a plastic bag, then seal and dispose of the bag.

ISO Coarse pre-filter

Carefully vacuum the ISO Coarse pre-filter once a week or replace it if it becomes too dirty or
damaged. Adjust the required cleaning intervals to the level of dirt if there are signs of dirt dur-
ing regular checks.

Order replacement filters here:

Содержание KA-520 L

Страница 1: ...g kleinste Partikel z B Bakterien Viren Pollen etc mithilfe eines Schwebstofffilters Hepa Filter aus der Luft Zur bestimmungsgem en Verwendung geh rt auch die Einhaltung aller Angaben in dieser An lei...

Страница 2: ...oder liegend ver wendet werden Auf die Unter seite m ssen die mitgelieferten Filzgleiter geklebt werden um Besch digungen am Boden zu vermeiden KA 520 XXL In die Ger teun terseite m ssen die beiliege...

Страница 3: ...Einfl ssen zu sch tzen Luftreiniger 5 Stunden vor der Wartung abschalten damit die im Filter enthaltenen Viren ab sterben Vollst ndig bedeckende Schutzausr stung lange rmel lange Hose Handschuhe Atem...

Страница 4: ...t use The air purifier KA 520 uses air circulation to filter the smallest particles e g bacteria viruses pollen etc out of the air using a particulate filter Hepa filter Intended use of the unit also...

Страница 5: ...t or lying horizontally Attach the felt gliders supplied to the un derside of the unit to prevent damage to the floor KA 520 XXL The adjustment feet supplied must be screwed into the underside of the...

Страница 6: ...ions to protect against harmful influences when changing the filter Turn off the air purifier 5 hours before maintenance so that the viruses contained in the filter can die off Wear full protective cl...

Страница 7: ...r que des liquides ou des produits de nettoyage inflammables ne s infiltrent dans l appareil Ne pas utiliser d eau de produits de nettoyage inflammables ou d autres li quides pour nettoyer l appareil...

Страница 8: ...acer l appareil uniquement sur un support horizontal stable le dos parall le ment au mur une distance de 15 cm Un p rim tre de 50 cm autour de la sor tie de l aspiration d air doit toujours tre d gag...

Страница 9: ...les in fluences n fastes teindre l purateur d air 5 heures avant la maintenance pour laisser mourir les virus pr sents dans le filtre Porter un quipement de protection recouvrant tout le corps manche...

Страница 10: ...met behulp van een filter voor zwevende deeltjes HEPA filter uit de lucht Tot het beoogde gebruik behoort ook het opvolgen van alle gegevens in deze handleiding Elk ander verdergaand of ander gebruik...

Страница 11: ...of liggend wor den gebruikt Aan de onderkant moeten de meegeleverde vilt glijders worden geplakt om be schadiging van de vloer te ver mijden KA 520 XXL De meegeleverde stelpoten moeten in de onder kan...

Страница 12: ...tegen schadelijke invloeden Schakel de luchtreiniger 5 uur v r het onderhoud uit zodat de virussen in het filter afster ven Draag volledig dekkende veiligheidsuitrusting lange mouwen lange broek hand...

Страница 13: ...apobiega pora eniu pr dem i przeciwdzia a zagro eniu po arem Zapobiega wnikaniu do urz dzenia cieczy lub palnych rodk w czyszcz cych Nie czy ci urz dzenia wod palnymi rodkami czyszcz cymi lub innymi c...

Страница 14: ...poziomym i stabilnym pod o u w odleg o ci co naj mniej 15 cm do ty u i z boku do ciany Obszar co najmniej 50 cm wok wlotu i wylotu powietrza musi pozosta wolny aby zapewni optymalne dzia anie urz dze...

Страница 15: ...e higieny aby chroni si przed szkodliwym wp ywem Wy czy urz dzenie do czyszczenia powietrza 5 godzin przed konserwacj aby obumar y wi rusy zawarte w filtrze Nosi ca kowicie zakrywaj ce wyposa enie och...

Страница 16: ...16...

Отзывы: