Kamoer Fluid Tech(Shanghai) Co., Ltd. DIP-KK300 V2 User Manual
14
indicates the baud rate index, the index is as follows: (the baud rate set here is the same as the baud
rate set in 485 Modbus)
0: 1200
1: 2400
2: 4800
3: 9600
4: 19200
5: 38400
6: 57600
7: 115200
Short press the rotary encoder to return to the function selection interface; long press the rotary
encoder (the setting takes effect) and return to the working interface.
Function
Display
Setting Description
13 is the menu number, 3 is the baud rate index,
which can be selected by the rotary encoder
8.
External control
485 communication control
Control the device through 485 communication, please connect the 485-communication cable.
Analog control
Control the device by analog signal (0-5V, 0-10V or 4-20mA), please connect the signal line according
to the actual control method.
9.
Dimensions