DIPump-KK300 V2
Intelligent Peristaltic Pump
User Manual
2023/02/13 V2.0
Kamoer Fluid Tech (Shanghai) Co., Ltd.
www.kamoer.com
Страница 1: ...DIPump KK300 V2 Intelligent Peristaltic Pump User Manual 2023 02 13 V2 0 Kamoer Fluid Tech Shanghai Co Ltd www kamoer com ...
Страница 2: ...incurred for product repairs 3 Non warranty coverage The following factors are not covered by the free warranty and customer repairs are subject to fees 1 Product appearance please confirm when purchasing 2 Improper use maintenance or storage please use maintain and store correctly according to the user manual 3 Access to inappropriate power supply 4 Damage to the components caused by the short ci...
Страница 3: ...encoder Foot switch External analog 485 communication control External analog signal control 0 5V 0 10V and 4 20mA Power failure parameter memory support Working mode speed mode flow mode Way of working Fully automatic cycle semi automatic cycle manual Support function Start stop Reversing Speed regulation Calibration Suck back Parameter memory Power supply mode External power adapter Power 50W 2 ...
Страница 4: ... working hours The first digit shows no beating the last three digits indicate the current remaining working hours The first digit is displayed and jumping the last three digits indicate the currently set stop duration The first digit shows when not beating the last three digits indicate the current remaining stop time The first digit shows no jumping the last digit indicates the selection of the ...
Страница 5: ...when the pump is stopped and started again Waterproof power interface DC 24V power adapter interface Combined control port The combined control port has 9 pins including 485 communication external start stop control analog signal control 0 5V 0 10V analog signal control 4 20mA functions The interface definition is shown in the figure below Foot 1 leave blank Foot 2 485 B Foot 3 485 A Pin 4 Foot sw...
Страница 6: ...4 Rotate the encoder to set the stop time the setting range is 0 999 seconds 5 Long press the encoder to return to the speed display interface and the running time and stop time will be saved automatically 6 Short press the encoder the pump will start to cycle according to the set running time and stop time 7 Short press the encoder the pump stops and the digital tube switches to the speed display...
Страница 7: ... range is 0 999 seconds 6 Long press the encoder to return to the flow display interface and the added amount and stop time will be automatically saved 7 Short press the encoder the pump starts to cycle according to the set addition amount and stop time 8 Short press the encoder the pump stops and the digital tube switches to the flow display interface Semi automatic cycle mode setting Just set th...
Страница 8: ...terface When the pump is stopped press and hold the rotary encoder for 2 seconds on the working interface to enter the running time setting interface runtime setting interface On the running time setting interface press and hold the rotary encoder for 2 seconds to enter the function menu selection interface menu selection interface The last 2 digits of the function menu selection interface are the...
Страница 9: ...enter the setting interface the first digit of the digital tube displays 2 the middle two spaces and the last digit Representative mode adjust the last 1 option through the rotary encoder to correspond to the low level running direction Short press the rotary encoder to return to the function selection interface long press the rotary encoder the setting takes effect and return to the working inter...
Страница 10: ...ce in the middle and the last 2 digits represent time seconds 3 When the pump is stopped it will switch to display speed RPM and 4 time every 2 seconds When the speed is displayed the rotary encoder can be rotated to change the speed When the time is displayed the rotary encoder can be rotated to change the time 4 After completing the setting short press the rotary encoder to start the flow calibr...
Страница 11: ... stop after power on again Short press the rotary encoder to return to the function selection interface long press the rotary encoder the setting takes effect and return to the working interface Function Display Setting Description 0 means do not save 1 means save C006 analog selection On the function selection interface rotate the encoder when the corresponding function of C006 is displayed as an...
Страница 12: ...ime is displayed to adjust the back suction time 0 99 seconds 5 When the back suction speed is displayed there is a decimal point between the third and fourth digits on the interface At this time rotate the rotary encoder to adjust the back suction speed 0 1 999 9ml min Short press the rotary encoder to return to the function selection interface long press the rotary encoder the setting takes effe...
Страница 13: ...terface rotate the encoder when the corresponding function of C012 is displayed as communication address setting short press the rotary encoder to enter the setting interface Enter the setting interface the last 3 digits represent the address adjust the communication address of the last 3 digits by rotating the rotary encoder the address selection range is from 1 to 247 short press the rotary enco...
Страница 14: ...interface long press the rotary encoder the setting takes effect and return to the working interface Function Display Setting Description 13 is the menu number 3 is the baud rate index which can be selected by the rotary encoder 8 External control 485 communication control Control the device through 485 communication please connect the 485 communication cable Analog control Control the device by a...
Страница 15: ...perature about 25 C using a new pump tube that has been aged for 30 minutes and tested water at 400 rpm for reference only Ambient temperature the material and elasticity of the pump tube the viscosity of the test liquid and other factors will affect the actual flow rate The thickness of the pump tubing will affect the actual maximum speed for stable operation ...
Страница 16: ...XiangJing Road Songjiang District Shanghai China Phone 86 021 67742578 Website www kamoer com Kamoer is a registered trademark of Kamoer Fluid Tech Shanghai Co Ltd The company reserves the right to improve and change product appearance and technical specifications without prior notice ...