Connect the tap water and underfloor heating
pipes
Note
Install the pipes in accordance with planning
documentation.
Note
Ensure the use of supplied seals when connecting the
pipes!
Note
Ensure that pipe insulation and fixing is made in
accordance with EnEV.
SI0000323
2
1
1.
Connect the tap water pipes to the tap water manifold by using
desired fittings.
2.
Connect the underfloor heating pipes to the underfloor heating
manifold by using desired fittings.
Connect the compression fittings
SI0000324
1
2
1.
Cut the pipe in required length.
2.
Connect the pipe to the manifold with the compression fitting.
Install the circulation line (optional)
SI0000326
1.
Connect the circulation line to the heat interface unit.
2.
Connect the circulation pump to the power supply.
Note
Please read the installation manual from the pump
manufacturer.