Note that when new batteries are inserted, the indicators may show 
the middle or low battery condition. This is because the power LEDs 
monitor the actual real-time battery usage, and when the unit is ac-
tually in use (phantom power, headphone amp, etc.), the true bat-
tery status will be shown.

Do not use the VU meter light more than necessary (this can 
result in considerable savings).

Turn off the power to the Kamesan KS-T2000 when it is not 
in use (“resting” the batteries can increase the battery life 
very significantly).

Setting the XLR output level switch to the 

+4

 setting can 

reduce battery consumption.

Cold batteries have a shorter life than warm ones. In winter 
or other cold conditions, you may want to keep the batteries 
warm when they are not in use. At 0°C (32°F), battery life is 
about 60% less than at 20°C (68°F).

As long as the connector conforms to the polarity of the 
Kamesan KS-T2000 connector (tip negative), a BP-90-type 
battery can be used for external power of the mixer.

The Kamesan KS-T2000 can use one of two optional external 
adapters:

PS-M12 mini power supply

SS-40611 MkII low noise power supply

Alternatively, any other power supply may be used (although this 
is not recommended), provided that it conforms to the following 
specifications:

Connector: BP-90 type with tip negative

Voltage: >9.0 V and <16.0 V

Power: >0.5 A

Any non-Kamesan AC adapter should also incorporate ripple 
reduction circuitry.

Extending battery life

Using an external battery

Using an AC adapter

Содержание KS-T2000

Страница 1: ...T2000 Compact Audio Mixer Operating Manual 3 2 0 VU 0 4 30 20 70 Dy M Dy M 4 30 20 4 70 30 L ine A B 8 4 P L i ne A B 8 4 P L ine A B 8 4 P Dy M MONI R L R L R L R L R L R L 20 70 0 5 40 0 5 40 0 5 4...

Страница 2: ......

Страница 3: ...hinner to clean the outside of the case Only use a soft damp cloth to wipe off any dirt or stains Only use power supplies batteries and external power sup plies as recommended in this manual Connectio...

Страница 4: ...itoring input 8 Output section 9 Output connections 10 Front panel 11 Batteries and power 12 Checking the batteries 12 Replacing the batteries 12 Extending battery life 14 Using an external battery 14...

Страница 5: ...k except using an AC adaptor authorized by Kamesan Always remove any dead batteries immediately from the Kamesan KS T2000 and remove any batteries from the unit if it will not be used for some time Co...

Страница 6: ...itself has been designed to be rugged and to stand up to the demands that will be made of it in its expected life Even so you should not drop the mixer or subject it to violent shocks or vibration Al...

Страница 7: ...o all other equipment turned OFF The mixer can accept a number of different sources at the three XLR input jacks The type of input for each channel is selected using the channel input mode selector ro...

Страница 8: ...e For full details of the levels impedances etc of these jacks see the section on Specifications on page 19 The illustration above shows the Kamesan KS T2000 connected to a pair of microphones as well...

Страница 9: ...e levels impedances etc of these jacks see the section on Specifications on page 19 See below for details of connections Output section MONI IN R L OUTPUT 60 4 60 4 DC IN L R MAS OUT Camera Mic DC inp...

Страница 10: ...You can use these different connectors for professional and semi professional video equipmen When you make the connections to the balanced connectors note that there are two switch positions for the l...

Страница 11: ...0 0 5 40 0 5 40 0 5 40 Headphone jack Monitoring on page 16 Monitor level Monitoring on page 16 Monitor selector Monitoring on page 16 Input trim control on each channel Adjusting the in put gain on p...

Страница 12: ...ation here The number of LEDs lit shows the battery status When only the bottom orange LED is lit it is time to replace the batteries with a new set 30 minutes to 1 hour s battery life remains If ther...

Страница 13: ...above with the polarity correct Never mix batteries of different types or discarded or par tially discharged and new or freshly charged batteries Always follow the battery manufacturer s instructions...

Страница 14: ...orter life than warm ones In winter or other cold conditions you may want to keep the batteries warm when they are not in use At 0 C 32 F battery life is about 60 less than at 20 C 68 F As long as the...

Страница 15: ...verheating and fire For this reason it is essential that only those adapters recommended and sold by Kamesan are used Connect the adapter connector to the DC IN connector of the Ka mesan KS T2000 maki...

Страница 16: ...er as described in Adjusting the input gain on page 17 Each input can be assigned to either the left master output the right master output or both Use the L and R switches to send the input signals to...

Страница 17: ...nsure that an appropriate monitoring mode is selected Monitoring on page 16 5 Turn down all input faders except the one which is to be adjusted which should be set to the nominal position 6 While the...

Страница 18: ...with the recorder connected to the outputs the mixer is fitted with an in tegral 1 kHz line up oscillator In order to see the output level using the oscillator 1 Make sure that both the OUTPUT level s...

Страница 19: ...AIN L R 4 60 dBm switchable transformer balanced Cannon 3 pin Unbalanced outputs 60 dBm compatible with impedance 600 to 10 k RCA pin jacks Monitor outputs 10 dBs 50 maximum 8 W stereo Maximum outputa...

Страница 20: ...nternal power supply 4 x type 3 AA dry cell batteries mounted in supplied standard battery holder Battery life Better than 6 hours with alkaline batteries at normal temperature conditions External pow...

Страница 21: ...GAIN 6V 48V DC Convert DC Convert 6V 12V 6V 12V POWER IND INPUT 1ch INPUT 2ch INPUT 3ch OUT L MAS OUT R MAS POWER SW MONI OUT P 48 MIC P 48 MIC P 48 MIC OUTPUT L OUTPUT R Convert A B MIC A B MIC A B M...

Страница 22: ...e heavy equipment ease of use since time is always of the essence in the environments where our products are used and quality to match the needs that today s broadcast ers require Our head office is i...

Страница 23: ......

Страница 24: ...Sigma Systems Engineering Co Ltd 3 5 2 Okubo Shinjuku ku Tokyo 169 0072 JAPAN Tel 81 3 3204 2611 Fax 81 3 3204 2250 e mail sales kamesan co jp...

Отзывы: