background image

 

Issue: July 2008 

Operating Instructions – CombiMag

 

Page 2 of 2 

 

COMBIMAG POWER FLUSHING FILTER (continued) 

 

 

 

Connecting the Filter 

The power flushing pump can circulate the system 
water in either direction by operation of the flow 
reversing lever. However we suggest that the initial 
set-up is such that the CombiMag filter is installed 
before the boiler to offer the boiler a higher level of 
protection in the early stages of the power flush. 

1.  Place the CombiMag power flushing filter 

adjacent to the power flushing pump on a suitable 
drip tray. 

2.  Select the required direction of flow and position 

the pump flow reverser lever in that direction. 

3.  Install the filter on the flow from the flushing pump 

using the short (1½ metre) hose supplied.  
Connect the flow to the bottom connection on the 
filter. 

4.  Using the power flushing pump standard flow and 

return hoses connect both the pump and the top 
connection on the CombiMag to the heating 
system. 

5.  Both CombiMag three- port valves should be in 

the 

CIRCULATE

 position. 

 

Operating Instructions

 

1.  Turn on the power flushing pump and 

immediately check all connections, and the top of 
the CombiMag cylinder for leaks. 

2.  After initial circulation for approximately ten 

minutes, turn both three-port valves 180° into the 

BYPASS

 position. 

3.  Remove the securing ring from the top of the 

cylinder and, gripping the handle firmly, carefully 
lift out the magnet. 

Note: the magnet is very powerful and is 
strongly attracted to steel surfaces. Take care 
not to trap fingers and avoid contact with 
sensitive equipment

4.  Inspect the magnet for collected deposits and, if 

necessary, clean as follows: 

 

5.  Grip the cylinder lid and handle with one hand. 

Whilst wearing disposable gloves, grip and slide 
the magnetite sludge down and off the magnet. 
Note: It is advisable to only remove a proportion 
of the deposits with each stroke, starting at the 
lower end of the magnet, rather than all at the 
same time. Clean the end of the magnet. 

6.  Collect the sludge in a suitable container for later 

disposal. 

 

7.  Re-assemble the CombiMag ensuring that the 

magnet locates within the circular recess at the 
base of the cylinder, and turn both three-port 
valves back into the 

CIRCULATE

 position. 

8.  Repeat the inspection and cleaning procedure as 

required during the flushing process. 

Cleaning the Magnet 

It is not necessary to remove all deposits during the 
intermediate cleans whilst power flushing. However, 
to ensure a long life the magnet should be 
thoroughly cleaned and dried at the end of each job. 

Caution 

The CombiMag contains a very strong magnet 
and generates a very powerful magnetic field. 
When removed from the cylinder, keep away 
from electronic equipment, watches, mobile 
phones, credit cards etc. 

 

Отзывы: