Fuse Replacement: 

Unplug the IEC power cable before replacing the fuse! Always replace with same type of fuse. 
1. Using a flat head screwdriver, remove the fuse holder from the IEC housing.  
2. Remove the bad fuse from the fuse holder. 
3. Insert the new fuse into the fuse holder. 

4. Install the fuse holder in the IEC housing. 

 
Mounting orientation: 

This fixture should only be mounted/used on a flat surface. This fixture should not be tilted. 

 
General maintenance 

To maintain optimum performance and minimise wear, the item should be cleaned frequently. Usage and environment are 
contributing factors in determining the cleaning frequency. As a general rule, fixtures should be cleaned after use to avoid dust build-
up and blockages, which can result in poor performance, overheating and breakages. Be sure to uplug the unit from the mains 

before

 conducting any maintenance. Use a vacuum and a soft brush to remove dust collected on external vents and internal 

components. Clean the external case when the unit has 

completely

 cooled down with a dry cloth or tissue.  

 

Regular maintenance 

Be sure to power off fixture 

before

 conducting any maintenance. Every 40 hours of continuous operation, it is recommended to run a 

cleaning solution

 composed of 80% 

distilled

 water and 20% distilled 

white vinegar

 through the system to prevent the 

accumulation of particulate matter in the heating element. 
 

The recommended cleaning regime is as follows: 
1. Empty all haze fluid from the machine.  
2. Add the above 

cleaning solution

 to the tank (80% 

distilled

 water and 20% distilled 

white vinegar

).  

3. Plug the unit in to the mains and allow it to warm up.  
4. Run the unit in a well-ventilated area until the tank is almost empty. 

Do not allow the pump to run dry.

  

Cleaning is now complete. Refill with haze/smoke fluid. Run the unit briefly to clear any cleaning solution from the system. 

 
Trouble shooting 

 

Symptom 

Solution 

No Power 

Check mains power. 
Check external fuse. 

No haze output 

Check fluid level. 
Check that there is no blockage in the system. 

Breaker/fuse keeps blowing 

Possible electrical short. Contact retailer/distributor for further instructions. 

Low haze output 

Run a cleaning solution through the unit. 
Check that the unit is plugged into the correct voltage. 

Haze machine is not heating up 

Check the external fuse. 
Possible faulty part. Contact your retailer/distributor for further instructions. 

Remote control does not work 

Make sure connector is firmly connected to device. 
Try using another controller. 
Possible faulty controller. 
Check the external fuse. 

 
 
Specifications and features 
 

Model 

Kam KHM400 

Power supply 

230V AC - 50Hz 

Power 

600w 

Re-heat time 

3-4 minutes 

Output 

2,500 CuFt per minute (approx) 

Tank capacity 

2.3 litres 

Manual haze button  

Yes 

Remote control 

Wired 

Weight 

5.3kg 

 
 

Отзывы: