Regular maintenance
Be sure to power off fixture
before
conducting any maintenance. Every 40 hours of continuous operation, it is recommended to run a
cleaning solution
composed of 80%
distilled
water and 20% distilled
white vinegar
through the system to prevent the
accumulation of particulate matter in the heating element.
The recommended cleaning regime is as follows:
1. Empty all haze/smoke fluid from the machine.
2. Add the above
cleaning solution
to the tank (80%
distilled
water and 20% distilled
white vinegar
).
3. Plug the unit in to the mains and allow it to warm up.
4. Run the unit in a well-ventilated area until the tank is almost empty.
Do not allow the pump to run dry.
Cleaning is now complete. Refill with haze/smoke fluid. Run the unit briefly to clear any cleaning solution from the system.
Trouble shooting
Symptom
Solution
No Power
Check mains power.
Check external fuse.
Check internal fuse.
No smoke/haze output
Check fluid level.
Check timer remote.
Check if there is any blockage in the system.
Breaker/fuse keeps blowing
Possible electrical short. Contact retailer/distributor for further instructions.
Low smoke output
Run a cleaning solution through the smoke machine.
Check that the smoke machine is plugged into the correct voltage.
Unit is not heating up
Check the external fuse.
Check the internal fuse.
Possible faulty part. Contact your retailer/distributor for further instructions.
Remote control does not work
Make sure connector is firmly connected to device.
Try using another controller.
Possible faulty controller.
Check the internal fuse.
Check the external fuse.
Specifications and features
Model
Kam KFHM1000
Power supply
230V AC - 50Hz
Power
1000w
Fuse
F5A
Re-heat time
2-3 minutes
Output
8,000 CuFt per minute (approx)
Tank capacity
2.5 litres
Timer remote
Yes
LED FX
Yes
Gross weight
6.63kg
Dimensions (WxHxD)
215 x 210.5 x 406mm