Diagram 01: 

the boiler is connected to a domestic hot w

ater tank and to the heating circuit.

 

            

The boiler is switched off when the contact (thermostat) is satisfied.

 The boiler is switched on when the contact (thermostat) detects a temper

ature 

            below SET 

ACS - ΔT (ΔT can be set by technical par

ameters).

a) 

To set the w

ater temper

ature in the boiler

, press the 

 k

ey

. Increase or decrease degrees with k

eys 

 and 

.

b)

 To set the desired temper

ature in the room (using the probe on the board) press the  

 ke

y. 

       Increase or decrease degrees with k

eys  

 and  

.

c) 

To set the work power press the  

  k

ey and adjust it with the 

 and  

 ke

ys. 

The rinsing from the stand-by state occurs automatically when a heat increase is required to return to satisfy the chosen stand-by condition (when this is set to ON) 

or when there is a health risk.

II

I

III

I = 

Valve motorization(4-5-6)

II = 

External thermostat On / OFF for stand-

by type 3 (optional) (1)

III = 

ON / OFF thermostat on DHW tank (2)

the scheme is indicative and w

ants to 

demonstr

ate only the components that can be 

managed by the boiler

. Any relay pumps must 

be controlled separ

ately from the boiler

6

3 vi

e

3 wa

y

comune - N

common - 

N

Lato sanitatio

DHW side

Lato riscaldam.

heating side

Sond

a

sup.

 puffe

r

Puffer 

uppe

r

prob

e

Termostat

o

estern

o

External

thermostat  

 

Sonda accumulo

 

sanitario o sonda inf. puffe

r

DHW probe or puffer 

lower prob

e

 

1

2

3

4

5

Содержание 24B

Страница 1: ...USER MANUAL Ilaria Nadia 24B 24BDD Boiler Stoves Instructions for the correct use and maintenance of your Kalor wood pellet boiler stove Distribution and warranty in Ireland by...

Страница 2: ...so offer a nationwide network of Authorised Technicians who are specially trained on Kalor wood pellet stoves This ensures that your stove can be correctly installed commissioned maintained and repair...

Страница 3: ...s in operation several parts of the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled...

Страница 4: ...for accidents deriving from the partial or total lack of observance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by...

Страница 5: ...hlike must be kept a suitable distance from the stove Risk of fire Carefully explain that the thermostove is made from ma terial subjected to high temperatures for the elderly the disabled and in part...

Страница 6: ...s prohibited The floor of the room where the thermostove is to be installed must be strong enough to take its weight If walls are flammable maintain a minimum distance of 10 cm at the rear A of 40 cm...

Страница 7: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Страница 8: ...be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics of c...

Страница 9: ...LERANZE GENERALI DI LAVORAZIONE DIMENSIONI LINEARI 0 15 0 05 3 2 0 1 DIMENSIONI ANGOLARI PRECISIONE 12 GRADO DI FINO A 0 15 0 1 6 0 3 0 25 120 0 2 0 15 60 6 60 0 3 0 2 0 5 4000 0 8 0 6 1000 400 0 5 0...

Страница 10: ...54 Pellet consumption min max Kg h 0 84 3 79 Heated surface mc 430 Flue gas flow rate min max g s 3 02 11 04 Draft min max Pa 3 8 Flue gas temperature min max C 51 1 103 Boiler water litri 31 Maximum...

Страница 11: ...ly connected to the system and to allow slighht movement Diagram connection kit without hot water thermostove Plumbing system connection There are 2 different types of systems Closed vessel system Ope...

Страница 12: ...3 bar the water used for filling the heating system must be decontaminated and without air When all the hydraulic connections are done proceed to test the pressure of the seals through the filling of...

Страница 13: ...sed If you have very extensive system with a large amount of water or which require frequent refilling it is recommended the installation of water softening system It should be noted that the encrusta...

Страница 14: ...termostato ext encoder ventilatore fumi encoder ventilatore fumi m 1 0 07 04 2017 P B C SCHEDA Q055 SCHEDA L023 LATO RISC Cn2 P2 P4 F P3 3VIE LATO SANIT N N TURBOLATORE OPZIONALE F PULITORE COMPATTAT...

Страница 15: ...IZED TECHNICIAN How to select the type of Stand by OPERATION BY A SPECIALIZED TECHNICIAN Press the SET button press button to go to menu 09 Press the SET button again Enter the access key and confirm...

Страница 16: ...adjust it with the e Reaction from the stand by state is when a heat increase is required to return to a chosen stand by condition when it is set to ON or when there is a health risk II I I Valve mot...

Страница 17: ...AM 25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PA...

Страница 18: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Страница 19: ...25 STAND BY IF PROBE H2O SET H2O a HEATING SANITARY HEALTH CALL ON 02 H2O WINTER ON IF H2O PARAM 25 MODULE IF PROBE H2O 80 C HEATING SANITARY SANITARIO NON CHIAMA OFF 03 TERM ES WINTER ON IF H2O PARA...

Страница 20: ...adjust it with the and keys The rinsing from the stand by state occurs automatically when a heat increase is required to return to satisfy the chosen stand by condition when this is set to ON or when...

Отзывы: