INSTALLATION INSTRUCTIONS
In-Wall Tank and Carriage
1206758-2-C
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4KALLISTA (1-888-452-5547) or kallista.com.
8 of 12
6. SECURE THE TOP OF THE CARRIAGE
2x4
Screws
Lag Bolt
1-5/8"
(41 mm)
Inlet
6" (152 mm)
Ø 2"
(51 mm)
Drill pilot holes at the lag bolt locations.
Install two 6” (152 mm) long support 2x4’s, located at the top of the carriage, aligned with the mounting
holes, 1-5/8” (41 mm) in from the front edge of the studs.
Secure the carriage to the support studs using 2” (51 mm) long (minimum) lag bolts (not supplied), one on
each side.
At the location of the inlet, drill a 2” (51 mm) hole.