background image

-4-

2.  Product Components

INSTRUCTION MANUAL

AIRFREE SERIES 

1

2

3

4

5

Metal Grid

Mounting bracket

PMSM motor

Fan blade

Winglet

 

1

2

3

4

5

Содержание AIRFREE Series

Страница 1: ...3 SHVLS FAN www kalefans net KaLe Environmental Technology Shanghai Corp Tel 86 18016245385 Fax 021 57685025 Web www kalefans net Email liumichael kalefans com Origin China ENGLISH SHVLS FAN KALEFANS...

Страница 2: ...uct Components 4 2 1 Components and Parts 5 2 2 Product Packing 6 3 Controller Panel nad Display Description 7 4 Product Operation 8 5 Safety Caution 8 6 Troubleshooting 9 6 1 Interpretation for Error...

Страница 3: ...ssesses relatively high cost performa passed the strict quality inspection and a variety of safety tests and you can rest assured If you have any questions and comments to our products contract us thr...

Страница 4: ...speed 7m s 1 5m s Driving Motor PMSM Motor Motor Power 0 55 kW Inner Power 1P AC220V Full load current 1 7 A Protection levels IP55 Wight 136kg Note 1 Weight the weight in table doesn t contain contro...

Страница 5: ...4 2 Product Components INSTRUCTION MANUAL AIRFREE SERIES 1 2 3 4 5 Metal Grid Mounting bracket PMSM motor Fan blade Winglet 1 2 3 4 5...

Страница 6: ...rts INSTRUCTION MANUAL www kalefans net a Stator axis b Rotor disc c Motor cover a b c Knob master switch Input wiring terminal Start speed regulating switch Output wiring terminal LCD screen Operatio...

Страница 7: ...ESCRIPTION NO DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 Packing Details Motor Fan adjusting base Blade retainer Connector Power cable Fasteners Controller Fan blade Steel mesh Extension tube Mouting brac...

Страница 8: ...d Lower left Voltage Right Accelerating Line1 Setting Line2 S00 Return Line3 S01 Rotating speed unlocked Line4 S02 Motor Self learning Top left Failure Code Lower left Please contact factory Right ER...

Страница 9: ...used next time Turn on the power and waiting more than 15mins to start the rotation Warning Before operation please read the manual very carefully Remove obstacles in the operating area to ensure tha...

Страница 10: ...tion as soon as possible cut o the power and contact KALE after sales service department Note Equipment damage caused by abnormal use is not contained by the product warranty of KALE FANS Our company...

Страница 11: ...nce Check the wiring of control circuit main circuit and ground remove interference source Notice this fault is detected when the output current of the controller exceeds the overcurrent point Code De...

Страница 12: ...orque increase V F curve setting is not appropriate To determine the relationship between voltage and frequency of V F curve setting modify F04 00 VF curve setting Modify the custom V F curve related...

Страница 13: ...n E oH2 IGBT module overheating Excessive ambient temperature Reduce the ambient temperature of the controller Overload Reduce load Decreased F01 40 Carrier Set Fan fault Make sure that the fan is run...

Страница 14: ...ed for free on the basic knowledge use and maintenance techniques of the equipment in a planned way and the relevant quali cations and certi cates of the equipment will be provided to ensure the long...

Страница 15: ...n should be done Product warranty Product warranty period 24 months For failures that occur during the warranty period please do not try to solve it by yourself Our company can send professional and t...

Отзывы: