![Kaldewei NEXSYS-SYSTEM Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/kaldewei/nexsys-system/nexsys-system_planning-instructions_3262981009.webp)
3.0
Installation Requirements
Inch = mm x 0,0394
Model No.:
a (mm)
b (mm)
2612
900
900
2615
1000
1000
2617
800
1200
2618
900
1200
2619
1000
1200
2623
900
1400
2624
1000
1400
2626
900
1600
Installation Situation
Systemcomponents
Installation Requirements
Position Waste Fitting
Height Adjustment
Slope of the Showertray-System
b
a
9/13 | ©
KALDEWEI.COM
| NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018
min. a + 20 mm
min. b + 20 mm
EH
Ø 50
mm
(Ø 40
mm)
i
i
c10
X
AH
EH
FA