0150-0138D
- 31 -
Calibur DVMRe
4
Alarms
4.1
Alarm Input
Alarm devices are connected via the Alarm PCB on the rear panel of the unit (see section 1.8). Each
Alarm Input corresponds with the Camera Input of the same number.
4.2
Alarm Output
Front Panel Alarm LED:
The LED located directly above the Alarm button is lit for the duration of the
alarm.
Internal Buzzer:
The internal buzzer is activated until it is Silenced and Acknowledged. This feature
can be turned off in the menu system (see Buzzer Setup in section 7.5).
Monitor Displays:
Discussed below in the
On-screen Displays During Alarms
section.
Output Relays:
The alarm output relays are active for the duration of the alarm. This feature is
configured in the menu system (see Alarm Action and Relay Configuration in section 7.5) and can be
deactivated.
Macro Activation:
Unit can be configured in the menu system to activate a macro when an alarm is
detected.
Record Rate:
Record Rate can be increased by recording at the Alarm Record Rate (see section 7.4)
and by Interleaved or Exclusive Recording (see Alarm Record mode in section 7.5).
4.3
Silence And Acknowledge
Pressing the
Alarm
button acknowledges to the unit that the alarm has been recognized and silences
the internal buzzer. This does not clear the alarm condition.
4.4
On-screen Displays During Alarms
10 and 16-Channel Units (Live or Recording)
Monitor-A Duplex / Monitor-A Simplex in Live Multiscreen Mode
4-Way
Single Alarm:
When a single alarm is received, the unit changes to 4-way
display containing the camera in alarm, and three associated cameras. The three
associated cameras are defined as a group in the menu system (see Alarm
Action in section 7.5). The top left cameo displays the camera in alarm.
Single Alarm
10-Way
Second Alarm:
When a second alarm is received, the unit changes to a 10-way
multiscreen, displaying the alarm cameras in the top two cameos. The
associated cameras are displayed in the remaining cameos.
Second Alarm
9-Way
Third Alarm:
When a third alarm is received, the unit changes to a 9-way
multiscreen, displaying the alarm cameras in the top three cameos. The
associated cameras are displayed in the remaining cameos.
More than three alarms simultaneously:
The unit switches to a sequenced full
screen display of all cameras in alarm.
Third Alarm