+1.800.868.1699
11
KalamazooGourmet.com
10
Bulk Gas Plumbing Information
IMPORTANT:
An installer-supplied safety shut-off valve MUST be installed on the gas supply
line for the cooktop unit.
The valve should be easily accessed and located between 3 and 20 feet
(.9 m to 6.1 m) away from the unit. All gas connections should be made by a qualified technician.
The installation and all installer-supplied parts must conform to local codes. In the absence of local
codes, the installation and all parts should conform to the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 or Natural Gas and Propane Installation Code, CSA B149.1. Cooktops to be connected to
a fixed fuel piping system must use rigid pipe, semi-rigid tubing, and/or a connector that complies
with the Standard for Connectors for Outdoor Gas Appliances and Manufactured Homes, ANSI
Z21.75/CSA 6.27.
IMPORTANT:
Always close gas supply shut-off valve before disconnecting the cooktop unit gas supply hose.
All pipe sealants must be an approved type.
IMPORTANT:
Diameter and length of the gas supply pipe may limit the pressure and BTU delivery of gas to
the cooktop unit. The installer must ensure proper delivery to the cooktop unit or it will not operate properly.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at pressures in excess of 1/2 psi (3.5 kPa). During any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa), the appliance
must be isolated from the system by closing its individual manual shut-off valve.
Gas Hose Assembly includes
-Gray gas hose
-Quick-Disconnect
-Gas Regulator
FIGURE 3
Installer-supplied shutoff
valve must be easily
accessible (not included)
Liquid Propane Gas Requirements
for Use with 20-Pound (9kg) Cylinder
Verify the type of gas your cooktop unit has been configured for by the factory by checking the
first page of this Use and Care Guide, or the serial plate located on the pull-out lighting instructions
plate underneath control panel. Gas appliances configured for liquid propane (LP) gas are orificed
differently than those configured for natural gas (NG). Cooktop units configured for use with a
standard 20-pound LP cylinder, equipped with a UL listed, Type 1, QCC-1 valve, are shipped with a
dual-stage LP regulator hose assembly (See Figure 2:B).
Connection:
LP regulator hose assembly (included) connects to the cooktop unit via a 3/8" male flare fitting.
Input Pressure:
11.0" W.C. (27.4 mbar)
To connect the LP regulator hose assembly to the LP tank, first make sure the main valve on the tank (Figure
2:A) is completely closed. Make sure also that all control valves on the front of the cooktop unit are OFF.
Thread the regulator inlet over the tank valve. Use care to ensure proper alignment of the threaded coupler
and avoid cross-threading or damaging the coupler. Turn the coupler clockwise until tightened up, but do not
over-tighten.
IMPORTANT:
Always close the main valve on the tank before disconnecting or transporting the tank.
IMPORTANT:
After connecting a fresh LP tank, you may need to purge air from the system. Before lighting,
open the main valve on the tank. Turn the control valves on the grill to the HIGH position for about 15
seconds to purge air from the system.
Turn the control valves on the grill OFF
and wait 5 minutes for any gas to clear.
Finally, continue with the normal lighting
procedure. The installation must conform
to local codes. In the absence of local
codes, the installation must conform
to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54; Storage and
Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58; Natural
Gas and Propane Installation Code,
CSA B149.1; or Propane Storage
and Handling, CSA B149.2.
A.
Main Tank Valve
B.
LP Hose and
Regulator Assembly
(Included)
FIGURE 2
A
B
Содержание K-CKTPD-3-NA-LPBLK
Страница 1: ...1 800 868 1699 1 Outdoor Cooktops U S E A N D C A R E G U I D E...
Страница 4: ...1 800 868 1699 5 KalamazooGourmet com 4 Safety Information...
Страница 9: ...1 800 868 1699 15 KalamazooGourmet com 14 Location and Installation...
Страница 13: ...1 800 868 1699 23 KalamazooGourmet com 22 Operation...
Страница 18: ...KalamazooGourmet com 32...