X K 3 1 9 0 - D S 1
35
11. Err 19 Can’t print due to 0 or negative value.
12. Err 28 Date for printing is less than saved date in indicator.
5.3 Code for wrong set up
1. Err P Wrong connection for printer or problem at printer. Press any key to exit.
2. Err 01 Load cell problem or load cell connection problem.
3. Err 05 The CPU chip for load cell communicating interface is broken.
5.4 Code for components error
1
.
Err 18 Key board has problems.
2
.
Err 22 Real clock damaged.
3
.
Err 23 E2PROM has been damaged.
4
.
Err 21 Calibration data lost.
5.5Code for others
1
.
Err 25 Illegal copied software or E2PROM was damaged.
2
.
ctnu 0 Indicator will display this if it can not receive the stable data within 25
seconds during step 8 or step 9 of the calibration process. At this time, the operator
can input 0, 1 or 2:
Input 0: (Abort) The indicator will not do this step and INPUT next step.
Input 1: (Retry) Try again
Input 2: (Ignore) The unstable data can be used.
3
.
ISP Indicator is at ISP satus.
Appendix : Weighing bill format examples
Record format
:
Weighing bill Date
:
2004-03-05
No. Time
Truck
No.
Cargo No. Gross(t) Tare(t) Net(t)
Client Note
Shanghai Xinxing Trading Company