X K 3 1 9 0 - D S 1
31
light will be on.
②
. Pre-tare
:
Press [pre tare] key at weighing status, indicator will display
. The
displayed data is the former tare weight. If you need to set new tare weight, just
input by numeric key and then press [input] to confirm.
③
. Call tare weight according to truck No.
Press[truck No.] at weighing status, indicator display
. Input truck
No. by numeric key and then press [tare]. Indicator will find out the corresponding
tare weight of the truck No. for use.
3.5.3.2 Continuous tare operation is permitted at weighing status. When tare weight is
0, tare light will be off. When indicator within manual zero range, press [zero] to
make tare weight as 0, then the tare light is also off.
3.5.4 Switch between N.W. display and G.W. display
Press [gross/net] key to switch between gross weight display and net weight display
3.5.5 Set for date and time
3.5.5.1 Indicator display the present date
and date light is on if you press
[date] key at weighing status. If the date is correct, you can exit by pressing [input]
or [weigh] key. If the date is not correct, Input the correct date by numerical key,
then press[Input ] key for confirm.Then indicator will display current Time
. If the time is correct, you can exit by pressing [input] or [weigh] key.
If the time is not correct, Input the correct time by numerical key, then press[Input ]
key for confirm.
3.5.5.2 You can press [date] key to switch among weighing display, date display and time
display if you just want to check the date or time without amendment.
3.5.6 Internal code display
3.5.6.1 The indicator will display internal code if you press [parameter] key and input
[2],[8] at weighing status. At this time the decimal point after the last number is on.
You can exit the “internal code” status by pressing [paraemter] key again, and input
[2 ], [8 ] key, the decimal point after the last number will be off. For example, display
12345. Means internal code. While display 12345 means weight.
At internal code display status, all other keys are invalid except [zero] key and
[parameter] key. 20 internal codes is equal to one division.
3.5.7 Static axis weighing