General Specifications
Operation temperature
: 32 ˚F to 104 ˚F (0 ˚C to 40 ˚C)
Storage temperature
: -4 ˚F to 140 ˚F (-20 ˚C to 60 ˚C)
Relative Humidity
: 0 % to 80 % at 32 ˚F to 95 ˚F (0 ˚C to 35 ˚C),
0 % to 70 % at 32 ˚F to 131 ˚F (0 ˚C to 55 ˚C)
Temperature Coefficient
: Nominal 0.1 x (Specified Accuracy) / ˚C (< 18 ˚C or > 28 ˚C ; < 64 ˚F or > 82 ˚F)
Max Voltage between
any input and Ground
: 300 V
Max Input Voltage
: 300 V
GMM Basic DC Accuracy
: 0.3 %
Bandwidth
: DC to 5 MHz (-3dB)
Max Sample rate
: 25 Mega sample/second
Graphing Multimeter
Display Counter
: 5,000 count
Display
: 280 x 240 pixels (active area) with backlit (EL)
Reference Waveform
: 51 Waveform
PC interface
: USB version 1.1
Power requirements
: Rechargeable Battery
(External AC to DC Power Adaptor)
Battery Life
: 4 Hours with backlit off
Size (H x W x D)
: 9.06 x 4.72 x 1.97” (230 x 120 x 50 mm)
Safety & design
: CAT II 300 V per IEC 1010-1, UL 3111-1 and C22.2 No. 1010-1
Accessory
User Manual
: 1 ea
AC to DC Power Adaptor
/Battery Charger
: 1 ea
Shielded Test Leads
: 2 ea (red and yellow)
Ground Leads
for Shielded Test Leads
: 2 ea (black)
Alligator Clips
: 3 ea (red, yellow and black)
8-1