background image

kaivac

TM

P a g e   ǀ  

9

kaivac

cleaning

systems

TM

1.5  s

Afety

 p

ReCAUtions

: b

AtteRy

 o

peRAted

 U

nits

 o

nLy

1.0  Getting Started

When using an electrical appliance, basic precautions should always be followed, including the following:

WARNING: 

To reduce the risk of fire, electric shock, or injury:

ONLY USE with Kaivac, Inc. battery, OBATT series, and charger, CHARG36V series.

When charging, make sure charger has at least 6 inches of clearance on all sides for adequate air flow.

DO NOT charge batteries outdoors.

DO NOT attempt to repair, service or modify the batteries or charger. Contact Kaivac Technical Support with any issues.

DO NOT short-circuit the battery or charger terminals with conductive items such as paper clips. This can deliver high

current, resulting in heat and fire.

Keep sparks and flames away from batteries.

DO NOT crush, drop, incinerate or damage the Battery Box. Do NOT use a Battery Box that has been damaged in any way. D

O

NOT incinerate the battery even if it is non-working or severely damaged. The battery can explode in a fire.

DO NOT expose a Battery pack or appliance to fire or excessive temperature. Exposure to fire or temperature above 2650

F

(1300C) may cause explosion.

DO NOT use or store the Battery in wet or moist conditions, or near flammable or combustible     materials.

DO NOT charge or store Battery Box for extended time (1 month or more) in temperatures below 400F (40C).

If fumes smelled from battery, discontinue use immediately, place inside a metal canister in a well-ventilated area.

Prevent unintentional starting. Ensure the switch is in the off-position before connecting to battery pack, picking up or car-

rying the appliance. Carrying the appliance with your finger on the switch, or energizing an appliance that has the switch on

invites accidents.

Disconnect the battery pack from the appliance before making any adjustments, changing accessories, or storing appliance.

Such preventive safety measures reduce the risk of starting the appliance accidentally.

When battery pack is not in use, keep it away from other metal objects like paper clips, coins, keys, nails, screws or other

small metal objects that can make a connection from one terminal to another. Shorting the battery terminals together may

cause burns or a fire.

Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with

water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.

Do not use a battery pack or appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredict-

able behavior resulting in fire, explosion or risk of injury.

C

harger/Electrical Warnings:

For commercial or residential use.

Connect charging cord to a properly grounded outlet only. See Grounding Instructions.

DO NOT plug in Charger while Vacuum Head is in ON position. It may damage the system.

Follow all charging instructions and do not charge the battery pack or appliance outside of the temperature range specified

in the instructions. Charging improperly or at temperatures outside of the specified range may damage the battery and 

increase the risk of fire.

DO NOT leave charger plugged in when not in use.

DO NOT operate charger if it has received a sharp blow, been dropped, or damaged in any way.

DO NOT use charger if it has a damaged cord or plug

DO NOT carry charger by cord.

DO NOT pull on charger cord to unplug. Grasp and pull the plug, not the cord.

DO NOT handle charger, including charger plug and charger terminals, with wet hands while charger is plugged in or while

inserting plug into electrical outlet.

Vacuum and operation warnings:

NO COMBUSTIBLES! Sparks inside the motor can ignite flammable vapors or dust. Do not use near combustible liquids and

gases, or to pick up explosive dusts or gasoline. Do not pick up anything that is burning or smoking such as cigarettes or hot 

ashes.

DO NOT plug Battery in while Vacuum Motor is in ON position. It may damage the system.

IMPORTANT SAFETY INSTRUCTIONS — SAVE THESE INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING (THIS APPLIANCE)

T: 

0121 351 4444 

   

E:

 [email protected] 

   

W: 

www. rawlins.co.uk

Содержание UNIVAC

Страница 1: ...kaivac cleaning systems TM UNIVAC OPERATOR PARTS MANUAL 2020 Kaivac Inc All rights reserved P N MANUALXCU ...

Страница 2: ...ook Ave Hamilton OH 45015 NOTE Specifications and parts are subject to change without notice Release No Date Revision Description 1 03 11 20 Initial design release of MANUALXCU 2 06 18 20 Edit to 4 1 4 2 and 4 3 T 0121 351 4444 E sales rawlins co uk W www rawlins co uk ...

Страница 3: ...tions Battery Operated Continued 10 1 6 Battery Information 11 2 0 Operation 2 1 Filling the Unit 12 2 2 Quick Change Power Pack Battery Charging 12 2 3 UniVac Operation 13 2 4 Emptying Vacuum Tank 14 3 0 Maintenance 3 1 Quick Change Power Pack Battery Electrical Diagram 15 3 2 AC Corded Electrical Diagram 16 4 0 Parts Diagrams and Specifications 4 1 Vacuum Tank Assembly Parts Diagram 17 4 2 Vacuu...

Страница 4: ...chasing a Kaivac product Please take a few moments to register your product at kaivac com warranty Why register Ensure your warranty coverage Simplify warranty service in the future with your information on file Be the first to know about upgrades issues new options and special offers T 0121 351 4444 E sales rawlins co uk W www rawlins co uk ...

Страница 5: ...s the replacement of the Battery unit Battery replacement remains under Warranty only for the remaining Warranty period of the original Battery unit for a maximum of 2 years from the date of purchase of the machine WARRANTY LIMITATIONS This warranty does not assume responsibility for damage or faulty performance caused by misuse or abuse or where repairs or modifications have been made or attempte...

Страница 6: ...liance make sure the connection is above the floor and away from exposure to liquid Keep all connections dry and off the ground To reduce the risk of injury close supervision is necessary when a product is used near children Stay alert watch what you are doing Keep operating area clear of all persons The Kaivac shall be disconnected from mains during cleaning or maintenance and when replacing part...

Страница 7: ...into the power cord If replace ment of the plug or cord is needed use only identical replacement parts Test the ground fault circuit interrupter GFCI before each use GROUND FAULT CIRCUIT INTERRUPTER PROTECTION for spray systems only This machine was supplied with a ground fault circuit interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the...

Страница 8: ...ry pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that can make a connection from one terminal to another Shorting the battery terminals together may cause burns or a fire Under abusive conditions liquid may be ejected from the battery avoid contact If contact accidentally occurs flush with water If liquid contacts eye...

Страница 9: ... the equipment QUICK RELEASE INSTRUCTIONS 1 To disconnect the motor from the Battery Pack pull the button on the electrical connector toward you and turn the electrical connector counter clockwise 90 degrees to disengage the motor electrical cord from the Battery Pack 2 Then to remove the Battery Pack from the OmniFlex unit detach the straps which wrap around the metal handle Then while standing a...

Страница 10: ...8VDC Keep Batteries at Room Temperature That means storing between 32 and 80 degrees F 00C to 270C The worst thing that can happen to a lithi um ion Battery is to have it exposed to elevated temperatures Batteries Lose Capacity Over Time Batteries naturally deteriorate over time whether being used or not Batteries deteriorate at a rate of 10 run time per year Fully Discharge vs Partial Discharge a...

Страница 11: ... Before filling with solution ensure the spigot is in the OFF position 2 2 Quick Change Power Pack Battery Charging Push tab on plug and pull to unplug head from battery Lift battery off machine mount Battery needs to be in unlock position to remove Push key IN and rotate counter clockwise to Unlock Once in place turn key clockwise to OFF to lock in place Lower battery into Charging Mount Ensure t...

Страница 12: ...N Attach Vacuum Wand to Vacuum Hose if not already connected Slap Tap Once Vacuuming is complete keep motor running Slap Vacuum Wand on floor 3 4 times to dislodge debris from squeegee head Then invert Wand and Tap 4 5 times to dislodge any fluids or substance from Wand Vacuum floor surface diagonally to grout lines reaching under shelves seating etc Then Turn OFF Motor Turn Spigot clockwise to th...

Страница 13: ...Once cap is removed lower Dump Hose into appro priate sink drain To prevent an accidental spill or overflow from the Dump Hose be careful to keep hose end upright until it is over sink drain To begin the dumping process you must first press down on the Cap and turn counter clockwise PRESS DOWN TURN 2 4 Emptying Vacuum Tank Before starting each new cleaning process remove Filter Bag dump any debris...

Страница 14: ...ck Red Red Black Orange Brown Black Black Black Red Blue White Green and Yellow 36VDC Thumb Lock Receptacle BATTERY PACK 36 VDC BMS INSIDE VAC HEAD POWER PACK INTERFACE 36VDC Thumb Lock Plug CHARGE IND USB JACK VACUUM MOTOR 14 24 23 13 MAGNETIC SWITCH I O IN OUT T 0121 351 4444 E sales rawlins co uk W www rawlins co uk ...

Страница 15: ...ǀ 1 6 3 2 AC Corded Electrical Diagram 3 0 Maintenance Black L Black L Black L Black N Black N Green GND Green Yellow Striped GND White N INSIDE VAC HEAD 120VAC PLUG VACUUM MOTOR T 0121 351 4444 E sales rawlins co uk W www rawlins co uk ...

Страница 16: ... FOR MOLDS AC ONLY 8 VHDTY VAC HOSE DRIP TRAY 9 CSS208 8 X 1 2 SS TRUSS SCREW 10 CSS365 1 2 13 SST LOCKING NUT DC ONLY 11 CSS40 1 2 DIA WASHER DC ONLY 12 OTKG UNIVAC OUTRIGGER TOE KICK GUARD DC ONLY 13 OBRAK OUTRIGGER BRACKET DC ONLY 14 OFCSTR2 OMNI 3IN CASTER NO BRAKE THREADED STEM DC 15 OEXTLEGB OMNIFLEX EXTENSION LEG B 16 OEXTLEGA OMNIFLEX EXTENSION LEG A ONLY 1 ON DC 17 OFCSTR OMNIFLEX 3IN CAS...

Страница 17: ...TEEL FLOAT CAGE 11 CSS313 SCREW 7 PANHEAD PHIL SS 1 2 IN 12 ZD10B OMNI VAC MOTOR BASKET 13 CSS315DC2 ELEC MALE PLUG 36VDC 20A 13 CSS315AU AUS PLUG IP44 13 CSS315UK UK PLUG IP44 PART NO PART DESCRIPTION 1 OBATT2 QUICK CHANGE POWER PACK 2 QCINTA QUICK CHANGE INTERFACE 3 CSS314DC2 METAL STRAIGHT ELEC FEMALE RECEPTABLE 36VDC 20A 4 CSS366 10 14 X 3 4 IN PLASTITE FLAT TORX 5 CHARG36VUL4 BATTERY CHARGER ...

Отзывы: