18
28
26
E
C
25
23
B
22
20
19
17
D
A
Cooling
While A,B,C…means different fan speed of outdoor unit.
7.4.2.3 Indoor fan running rules
For Console:
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
When the compressor is running, the indoor fan is controlled as below:
The auto fan acts as below rules:
a
b
c
d
5.0
4.0
2.5
1.0
6.0
T1-Ts
e
H
(H-L)*0.75+L
(H-L)*0.5+L
(H-L)*0.25+L
L
For other models:
Indoor fan keeps running, fan speed can be set in high/mid/low/ Auto by using a remote controller:
Auto fan in cooling mode acts as follow: