KaiCong—Nothing important than safety!
!
5.1 Setup of the OSD Menu
5.1.1 Protocol
(1) Braud Rate
The baud rate is determined based on the ball machine DIP switch. When the baud rate DIP switch DIP nobody any
baud rate of automatic identification
Data bits: 8
Parity: without
Stop bits: 1
(2) Protocol
PECOL-D, pecol-p, SAMSUNG, B01, HIKVISION, DAHUA.
!
5.1.2 PTZ Control
Left, Right, Auto flip.
5.1.3 Camera control
TELE WIDE NEAR FAR OPEN CLOSE, NEAR FAR
5.1.4 Presets
Set, call, delete
5.2 Running setup
5.2..1 Presets
Support 220 persets, Call or set up preset point No. 66- No.99 (special preset point of system) to open the menu.
!!
2. The operation process of presets:
(1) Set up preset points
Shake the keyboard joystick or other control software to make PTZ reach a region. Enter the point ID on the
keyboard or other control software and press “install” or “SET” button. Set the current preset point, and the PTZ
will save the zoom of the camera to a specific point ID.
(2) Call preset points
Enter the point ID on the keyboard or other control software and press “transfer” or “CALL” button. And the PTZ
will jump to the position which the presets had set before. If the point ID is not set before, the OSD will show "not
set"
(3) Delete preset points
Enter the point ID on the keyboard or other control software and press “delete”, then the change of preset points
will be deleted.
5.2.2 Cruise function of preset points
The product supports 9 cruise functions of presets points and each cruise trajectory can edit 16 preset points.
It will make the corresponding presets jump one by one according to priority. 16 preset points should be set by
cruise function one by one. If the preset point number is not set, it will jump directly to the next set preset point.
Concerning the cruise function configuration, please see the cruising scan settings of the menu.
5.2.3 Function of sweep scan
The product supports 16 sweep scan. It finishes the action of scanning by PTZ between two points.
You should pre-set the start point, end point and the DIA. The zoom of camera will change according to the
camera of the start point and the one of the end point will never change. Please see the menu of sweep scan
function configuration behind.
!
5.2.4 Function of rotate scan (360°)
The product support 8 rotate scan, which scan by 360°. You need pre-set the start point, end point and the DIA
(Clockwise or counterclockwise). See the menu about the details.
!
5.2.5 Function of pattern scan
The product supports 4 pattern scan. Every pattern scan can record 450 mandates for 10 minutes. It includes 2
phases. The first one is record, which will record all mandates of control that the product receives. The second one
is playback, which will execute the mandates circulating. See the menu about the details.
!
5.2.6 Timing functions
The product supports 4 timing functions. It can specify the machine reaches a certain point and perform the
appointed action in time. You need to set start time, end time and time mode (Appointing one appointed day to
start the function). When the system clock reaches the start time, it will perform the appointed action. And when it
reaches the end time, it will finish the action. Concerning timing function configuration, see the menu behind.
!
8