background image

KaiCong—Nothing important than safety!

!

4 Installation Preparations 

4.1 Tool List 

(The tools in the list will be used or not) 
(1) Screws                       (2) Monkey wrench  
(3) Philips screwdriver    (4) Straight Screwdriver  
(5) Wire stripper              (6) Ladder  
(7) Electric drill               (8) Socket head wrench  
(9) Hammer                    (10) Electric iron  
(11) BNC mail connector  

!

4.2 Installation Preparation 

(1) Check the space and toughness of the site Make sure that the environmental conditions meet the installation requirements for this 
product. 
(2) Please check the space and toughness of the site before installing. It should be able to bear 4 times the weight of the PTZ and its 
accessories. 

4.3 DIP Switch Setup 

(1)Default: Pelco P/D auto detected, baud rate: 2400bpx, address: 1. Detach the upper housing and bottom cover, you can see DIP 
switch below  

 

!!

!!

!!

!!

!!

!!

!!

!!

!!

!

!

(2)Baud Rate Setup 
Decoder Switch: 9~10 (1=ON, 0=OFF) 

!

Notice: Please restart the camera after setting switch. 
(3) When the DIP Switch 9th and 10th are ON, the PTZ can automatically detected the baud rate 2400, 4800,9600,19200.

Switch 9-10 setting

Baud Rate

Max transmission distance(M)

9

10

0

0

2400BPS

1800

1

0

4800BPS

1200

0

1

9600BPS

800

1

1

Auto detected 2400

4800

9600

19200BPS

600-1800

7

DIP Switch Position

Reset Position

Содержание ZT01

Страница 1: ...g Nothing important than safety ZT01 Auto Tracking IR High Speed Dome Camera User Manual KaiCong Electronic Technology Co LTD ZT01 Automatic Tracking Ball Manual two dimensional code December 19 2013...

Страница 2: ...Nothing important than safety Packing PTZ 1 Wall Bracket include fixed Screws 1 Holder 1 DC12V 5A power supply 1 Screws 4 PM8 25 socket head screws 4 User s manual 1 Warranty Card 1 Conformity of qual...

Страница 3: ...7 4 2 Installation Preparation 7 4 3 DIP Switch Setup 8 5 Setup of the OSD Menu 9 5 1 Display Boot UP Info 11 5 2 Enter the OSD Menu 13 5 3 SYSTEM 15 5 4 LENS 17 5 5 CAMERA 17 5 6 PAN TILT 18 5 7 AUTO...

Страница 4: ...space and toughness of the site before installing It should be able to bear 4 times the weight of the dome and its accessories Please keep all the original dome package materials for future repacking...

Страница 5: ...cruise scan 27 presets group 4 group patterns one scan and 360 continuous scan and 360 intermittent scan IR lights automatically adjust the light intensity according to the zoom speed to reduce the d...

Страница 6: ...cation PELCO D P auto detected Baud Rate 2400bps 4800bps 9600bps 19200bps Address 1 255 RTC Set any functions at any time IR Light switch A Superpower LED Default 1 5 times open the near distance ligh...

Страница 7: ...ace and toughness of the site before installing It should be able to bear 4 times the weight of the PTZ and its accessories 4 3 DIP Switch Setup 1 Default Pelco P D auto detected baud rate 2400bpx add...

Страница 8: ...l make the corresponding presets jump one by one according to priority 16 preset points should be set by cruise function one by one If the preset point number is not set it will jump directly to the n...

Страница 9: ...the lens will automatically flip 180 horizontally then the user can still control it to move upwards till 90 which enables the user to directly observe the situation on the back side thus fore and af...

Страница 10: ...e to present menu to Display Setup chose OPEN IRIS OPEN into the Submenu Move to the menu which you will change it choose OPEN to get in the present menu Press to open the Modify button to enter the v...

Страница 11: ...pen Presets Display 3 seconds Angle Zoom Display 3 seconds Alarm Display 3 seconds Regional Prompt Close Camera Title Location Display Setup Back Exit Camera Title Setup Camera Title _ _ _ _ _ _ _ Inp...

Страница 12: ...rame Then unfreeze the frame after it reaches the preset point Soft addr switch Turn on the switch the function of soft address is open The value is the value of the menu SOFT ADDR When you cancel thi...

Страница 13: ...press IRIS CLOSE to cancel the setting IR MODE Define the mode of IR brightness Auto IR brightness read the environmental condition at regular time according to the value that SCAN TIME has set If it...

Страница 14: ...d move the joystick up and down to select the value of N THRESHOLD The threshold level of IR brightness turning on 5 Advance Setup Press IRIS OPEN to enter advance control Move to menu item press IRIS...

Страница 15: ...n Detection Setting detaching attribute of motion object 15 Main Menu System Info Display Setup Control Setup Camera Setup Run Setup Other setup Language Setup Chinese System Restart Restore factory s...

Страница 16: ...N to modify the value of the corresponding menu item move the joystick up and down left and right to modify the value press IRIS OPEN to confirm and save and press IRIS CLOSE to cancel the setting REG...

Страница 17: ...ify the value of the corresponding menu item move the joystick left and right to select POS STATE TIME and SPEED move the joystick up and down to select the value press IRIS OPEN to confirm and save a...

Страница 18: ...8 rotate scan SCAN SPEED setting scan speed level of 360 64 levels in total SCAN DIR direction of scan Clockwise or anticlockwise SET START POS setting the start position of rotate scan Press OPEN to...

Страница 19: ...8 zones by turns STATUS TIME the status time of the zone DETE ACH REGION setting the detach region of the zone Every zone has 4 regions SET ZONE setting the zone DELETE ZONE delete the zone START sta...

Страница 20: ...k to make one region of the lens move press IRIS OPEN to enter the configuration of region s size at this time there will be a black region in the middle of the screen move the joystick up and down le...

Страница 21: ...n needs support of the camera It just supports SONY NEWLG camera privacy setup so far SONY camera support setting in the dome 8217 s menu but NEWLG cameras need to be set in the menu with itself 21 OT...

Страница 22: ...0 0 1 1 0 0 0 0 13 1 0 1 1 0 0 0 0 14 0 1 1 1 0 0 0 0 15 1 1 1 1 0 0 0 0 16 0 0 0 0 1 0 0 0 17 1 0 0 0 1 0 0 0 18 0 1 0 0 1 0 0 0 19 1 1 0 0 1 0 0 0 20 0 0 1 0 1 0 0 0 21 1 0 1 0 1 0 0 0 22 0 1 1 0 1...

Страница 23: ...0 1 0 91 0 0 1 1 1 0 1 0 92 0 0 1 1 1 0 1 0 93 1 0 1 1 1 0 1 0 94 0 1 1 1 1 0 1 0 95 1 1 1 1 1 0 1 0 96 0 0 0 0 0 1 1 0 97 1 0 0 0 0 1 1 0 98 0 1 0 0 0 1 1 0 99 1 1 0 0 0 1 1 0 100 0 0 1 0 0 1 1 0 10...

Страница 24: ...0 0 0 0 0 0 1 0 1 161 1 0 0 0 0 1 0 1 162 0 1 0 0 0 1 0 1 163 1 1 0 0 0 1 0 1 164 0 0 1 0 0 1 0 1 165 1 0 1 0 0 1 0 1 166 0 1 1 0 0 1 0 1 167 1 1 1 0 0 1 0 1 168 0 0 0 1 0 1 0 1 169 1 0 0 1 0 1 0 1 17...

Страница 25: ...1 1 1 0 1 1 221 1 0 1 1 1 0 1 1 222 0 1 1 1 1 0 1 1 223 1 1 1 1 1 0 1 1 224 0 0 0 0 0 1 1 1 225 1 0 0 0 0 1 1 1 226 0 1 0 0 0 1 1 1 227 1 1 0 0 0 1 1 1 228 0 0 1 0 0 1 1 1 229 1 0 1 0 0 1 1 1 230 0 1...

Страница 26: ...ling configuration No 68 Enter the entrance of starting rotate scan No 69 Enter the entrance of starting sweep scan No 70 Enter the entrance of starting preset point cruise No 71 Enter the entrance of...

Страница 27: ...AUTO FILP No 5 open language configuration switch No 6 close language configuration switch No 7 open auto protocol identification No 8 close auto protocol identification No 9 retain No10 retain No 11...

Страница 28: ...t ID then calling sub point I D i n t h e 1 5 seconds Now you ve got it No 1 enter camera menu camera supported No 2 open CAMERA OSD No 3 close CAMERA OSD No 4 open camera DIGITAL ZOOM No 5 close came...

Страница 29: ...6 point ID and then calling sub point ID in the 15 seconds Now you ve got it No 1 Recognize the camera automatically No 2 SONY18X No 3 CNB22X No 4 SAMSUNG231 No 5 HITACHI454 No 6 SANYO400 No 7 SAMSUNG...

Страница 30: ...y 3 No 4 Set the IR detection sensitivity 4 No 5 Set the IR detection sensitivity 5 No 6 Set the IR detection sensitivity 6 No 7 set IR AUTO mode No 8 set IR MANUAL OPEN mode No 9 set IR MANUAL CLOSE...

Страница 31: ...scan No 2 Start the 2nd sweep scan No 3 Start the 3rd sweep scan No 4 Start the 4th sweep scan No 5 Start the 5th sweep scan No 6 Start the 6th sweep scan No 7 Start the 7th sweep scan No 8 Start the...

Страница 32: ...Start the 4th curies No 5 Start the 5th curies No 6 Start the 6th curies No 7 Start the 7th curies No 8 Start the 8th curies No 9 Start the 9th curies No 10 255 retain entrance of point ID Sub point I...

Страница 33: ...Wrong contact of power cables Correct Power supply adaptor damaged Replace Damaged assurance pipeline Replace Bad contact of power cables Exclude Normal self check and image but out of control wrong s...

Страница 34: ...scan 4 Set 88 preset Set cruise 1 Set 89 preset Set cruise 2 Set 90 preset Set cruise 3 Set 91 preset Set cruise 4 Set 94 preset Set color to black function Set 95 preset Close main menu Set 96 preset...

Страница 35: ...safety Call 93 preset Set right limit Position Call 94 preset Camera IR CUT switch Call 95 preset Open main menu Call 97 preset Call all valid presets cruise Call 98 preset Call 360 scan Call 99 pres...

Страница 36: ...correct RS485 cable wiring 1 Reset the DIP Switch according to the DIP switch chart 2 Check 485 bus controls 3 Check the wiring 4 Check the control device Some function is out of control 1 RS485 commu...

Страница 37: ...nology Co LTD Address Jinsha Road Jiading District Shanghai 2890 Lane 35 Room 320 Regent Tel 4006 58 23 58 Fax 021 51026530 KaiCong LTD Official Website Http www KaiCong net KaiCong Official Forums Ht...

Отзывы: