KaiCong—Nothing important than safety!
!
4 Installation Preparations
4.1 Tool List
(The tools in the list will be used or not)
(1) Screws (2) Monkey wrench
(3) Philips screwdriver (4) Straight Screwdriver
(5) Wire stripper (6) Ladder
(7) Electric drill (8) Socket head wrench
(9) Hammer (10) Electric iron
(11) BNC mail connector
!
4.2 Installation Preparation
(1) Check the space and toughness of the site Make sure that the environmental conditions meet the installation requirements for this
product.
(2) Please check the space and toughness of the site before installing. It should be able to bear 4 times the weight of the PTZ and its
accessories.
4.3 DIP Switch Setup
(1)Default: Pelco P/D auto detected, baud rate: 2400bpx, address: 1. Detach the upper housing and bottom cover, you can see DIP
switch below
!!
!!
!!
!!
!!
!!
!!
!!
!!
!
!
(2)Baud Rate Setup
Decoder Switch: 9~10 (1=ON, 0=OFF)
!
Notice: Please restart the camera after setting switch.
(3) When the DIP Switch 9th and 10th are ON, the PTZ can automatically detected the baud rate 2400, 4800,9600,19200.
Switch 9-10 setting
Baud Rate
Max transmission distance(M)
9
10
0
0
2400BPS
1800
1
0
4800BPS
1200
0
1
9600BPS
800
1
1
Auto detected 2400
、
4800
、
9600
、
19200BPS
600-1800
7
DIP Switch Position
Reset Position