Event Recognition and Fault Rectification
9 --- 44
9
Event Recognition and Fault Rectification
Inform KAESER service if the event cannot be rectified by the action suggested.
Do not attempt rectifications other than those given in this manual.
The measures valid for your machine are dependant on the individual equipment.
There are three types of event:
Description
Indicated by
see chapter
An event that triggers an alarm (with automatic
shut ---down)
Blinking red LED
9.1
An event that triggers a warning (no shut ---
down)
Blinking yellow LED
9.2
Miscellaneous events (faults)
No indication
9.3
9.1
Alarm messages to the controller
(machine shut ---down, red LED blinking)
Message
Possible cause
Remedy
access doors
Door open with the machine
running.
Close the door(s).
ADT
Maximum airend discharge
temperature exceeded.
Ensure adequate ventila-
tion.
Ensure that the permissible
room temperature is not ex-
ceeded.
Clean the cooler.
Cooling air outlet of the ma-
chine too near a wall.
Check the cooling oil level.
ADT dT/dt
Maximum rise rate of airend
discharge temperature
(ADT) exceeded.
Check airend and piping to
airend.
Check the cooling oil level.
Check oil circulation.
AI 3/AI 4 error
Line---break between the
analog input and the sen-
sor.
Short circuit to earth.
Check transducer connec-
tions and wiring.
AI 7/AI 8 error
Line---break between the
analog input and the sen-
sor.
Short circuit to earth.
Check transducer connec-
tions and wiring.
airend rotation
The drive motor is turning in
the wrong direction.
Change over phase lines L1
and L2.
air filter dp
Air filter clogged.
Clean or renew the filter el-
ement.
backpressure
Back pressure in the oil
separator tank caused by
poor venting.
Check venting line.
Buscontroller
Bus link via the Profibus DP
interface
Check line and settings.
Содержание CSD 102
Страница 2: ......
Страница 85: ......
Страница 86: ......
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 94: ...Annex 13 86 13 Annex 13 1 Diagrams and Drawings 13 1 1 Pipeline and instrument flow diagram P I diagrams...
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ...Appendix 13 92 13 1 2 Pipeline and instrument flow diagram option C1...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ...Appendix 13 98 13 1 3 Dimensional drawing 13 1 3 1 Air cooling option K1...
Страница 107: ......
Страница 108: ......
Страница 109: ...Appendix 13 101 13 1 3 2 Water cooling option K2...
Страница 110: ......
Страница 111: ......
Страница 112: ...Appendix 13 104 13 1 4 Electrical diagram...
Страница 113: ......
Страница 114: ......
Страница 115: ......
Страница 116: ......
Страница 117: ......
Страница 118: ......
Страница 119: ......
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ......
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......