2. Using the «Up» or «Down» keys, select the line
Operating mode:.
The source for the speed setting will be displayed in the line
Operating mode:.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
10.1.1 Power switching
▶5 Softstart
▶6 Customer-provided
·········
Operating mode:
Pressure control
Source for speed setting
Nominal value:
3. Press the «Escape» key repeatedly to exit the menu.
9.10 Setting the maintenance interval
Maintenance comprises a set of tasks that must be completed in order to ensure the function‐
ality of a machine or system.
A maintenance interval is a period of time specified by the manufacturer, at the end of which
a maintenance task falls due.
Example: Changing the oil change service interval.
Precondition Access level 2 is activated.
The operating mode is displayed
NOTICE
Unauthorised extended maintenance intervals
Progressive damage to the machine leading to inoperability
➤ Observe the maintenance intervals specified by the manufacturer
Maintenance menu
1. Open the menu 4
Maintenance.
2. Using the «Up» or «Down» keys, select the line
Oil change.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
4 Maintenance
Oil change
active line, Description maintenance interval
3000h¦
0150h
Reset:
☐
Preset interval 3000 h
·········
Air filter
3000h¦
0150h
Reset:
☐
Prefilter changed:
☐
9
Operation
9.10 Setting the maintenance interval
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
187