background image

Kaden Installation Manual  | 

37

KSI18, KSI24, KSI28 Outdoor unit wiring diagram: 16022000033970 

Compressor

U

V

W

Blue

Blue

Red

Black

Red

Black

W

CN21

CN6 CN7 CN8 CN2

CN3

Y/G Y/G

Blue

Brown

Black

Optional

DR model

CN23

4

4

For user

to connect

CN4

L

N

S

CN2-1 CN2-2 CN2-3

DR

CN3

RJ45

1(L) 2(N) S

L N

Optional

4-way

Blue

CN60

Optional

Red

CN16

White

CN19

Optional

Optional

Optional

Crankcase

heater

Pan

heater

Optional

Y/G

CN5

Optional

2/3

4/5

AC-fan

Yellow/white

Capacitor

CN18

Electronic

expansion valve

optional

Optional:

AC-fan

CN414

CN17

3

5/6

Red

Optional

DC-fan

DC-fan

- - - - 

This symbol indicates the 

element is optional, the actual 

shape shall prevail.

16022000033970

Y/G

Y/G

To indoor unit power supply

Optional

Optional

Discharge temp. sensor

Ambient temp sensor

Condenser temp. sensor

Outdoor

main 

PCB

Содержание KSI Series

Страница 1: ...Installation Manual R32 WALL MOUNTED AIR CONDITIONER KSI Series KSI06 KSI09 KSI12 KSI18 KSI24 KSI28...

Страница 2: ...000 AS NZS 5149 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed only by an Authorised Person For continued safe...

Страница 3: ...Pay attention to line wire 24 7 Refrigerant piping connection 25 Note on pipe length 25 Connection instructions refrigerant piping 25 Minimum bend radius 27 Instructions for connecting piping to indo...

Страница 4: ...ed licensed personnel should install service or carry out maintenance to this air conditioning unit All electrical work is to follow local and national wiring standards and the Installation Manual 7 Y...

Страница 5: ...ARC Australian Refrigeration Council licence holders can install and commission this air conditioner This air conditioner must be installed to meet the requirements of the current version of AS NZS 51...

Страница 6: ...may result in water leakage electrical shock and fire or cause the equipment to fail Name of Accessories Qty pc Shape Mounting plate 1 Clip anchor 5 Mounting plate fixing screw ST3 9 X 25 5 Remote co...

Страница 7: ...planatory purposes The actual shape of your indoor unit may be slightly different Wall mounting plate Front panel Louvre Functional filter on back of main filter some units Drainage pipe Signal cable...

Страница 8: ...nstallation Manual 4 Installation summary indoor unit 1 2 Select installation location page 11 Determine wall hole position page 11 3 4 Attach mounting plate page 12 Drill wall hole page 12 10cm 12cm...

Страница 9: ...Kaden Installation Manual 9 Connect piping page 26 Connect wiring page 17 Prepare drain hose page 15 Wrap piping and cable page 19 Mount indoor unit page 19 1 2 3 5 8 9 6 7 STEP 8...

Страница 10: ...sturb other people Firm and solid the location will not vibrate Strong enough to support the weight of the unit A location at least one meter from all other electrical devices e g TV radio computer DO...

Страница 11: ...the indoor and outdoor units 1 Determine the location of the wall hole based on the position of the mounting plate Refer to mounting plate dimensions on the next page to help you determine the optima...

Страница 12: ...g with the following dimensions Width of mounting plate Height of mounting plate Width of indoor unit relative to plate Height of indoor unit relative to plate Recommended position of wall hole both t...

Страница 13: ...allation Manual 13 Model A KSI06 KSI09 KSI12 Model E KSI18 KSI24 KSI28 71 6mm 377 8mm 338 2mm 346 8mm 453 2mm 406 4mm 25 7mm 531 0 5mm 65mm 645 1mm 65mm 65mm 65mm 65mm 65mm 429 5 0 5mm 54mm 285 0 5mm...

Страница 14: ...nding them away from the unit Any dents in the piping will affect the unit s performance Step 5 Connect drain hose By default the drain hose is attached to the left hand side of unit when you re facin...

Страница 15: ...d the air conditioner 9 Every wire must be firmly connected Loose wiring can cause the terminal to overheat resulting in product malfunction and possible fire 10 Do not let wires touch or rest against...

Страница 16: ...with the specifications mentioned below 4 core 1 5mm conformed with 60245 IEC57 1 Earth wire is included yellow green 2 Arrange each wire length as shown below Make sure that each wire is stripped 10...

Страница 17: ...through this slot from the back of the unit to the front 6 Facing the front of the unit connect the wire according to the indoor unit s wiring diagram connect the u lug and firmly screw each wire to i...

Страница 18: ...es drain hose and signal wire through the hole in the wall 4 Hook the top of the indoor unit on the upper hook of the mounting plate 5 Check that unit is hooked firmly on mounting by applying slight p...

Страница 19: ...ed area snowfall The minimum height must be 46cm DO NOT install unit in the following locations Near an obstacle that will block air inlets and outlets Near a public street crowded areas or where nois...

Страница 20: ...nd of the drain joint that will connect to the outdoor unit 2 Insert the drain joint into the hole in the base pan of the unit 3 Rotate the drain joint 90 until it clicks in place facing the front of...

Страница 21: ...8 890x673x342 663 354 If you will install the unit on the ground or on a concrete mounting platform do the following 1 Mark the positions for four expansion bolts based on dimensions in the unit mount...

Страница 22: ...ICAL WORK READ THESE REQUIREMENTS 1 All wiring must comply with local and national electrical codes and must be installed by a licensed electrician 2 All electrical connections must be made according...

Страница 23: ...etal or plastic conduit is used with no more than three cables contained in a conduit and a voltage drop of 2 Preparing cable 1 Selecting cable Select the power source cable and connecting cable in ac...

Страница 24: ...the terminal 5 Using the cable clamp fasten the cable to the unit Screw the cable clamp down tightly 6 Insulate unused wires with PVC electrical tape Arrange them so that they do not touch any electr...

Страница 25: ...piping Maximum length and drop height of refrigerant piping per unit model Model Capacity kW Min length m Max length m Max height difference m KSI06 2 0 3 25 10 KSI09 2 6 3 25 10 KSI12 3 5 3 25 10 KS...

Страница 26: ...rials from entering the pipe 2 Sheath the pipe with insulating material 3 Place flare nuts on both ends of pipe Make sure they are facing in the right direction because you can t put them on or change...

Страница 27: ...g radius is 10cm Instructions for connecting piping to indoor unit 1 Add refrigerant oil to the flare faces 2 Align the centre of the two pipes that you will connect 3 Tighten the flare nut as tightly...

Страница 28: ...the flare nut as tightly as possible by hand 5 Using a spanner grip the body of the valve Do not grip the nut that seals the service valve USE SPANNER TO GRIP MAIN BODY OF VALVE Torque from tightening...

Страница 29: ...eak detector and bubble solution Safely release the test pressure 4 Open the Low Pressure side of the manifold gauge Keep the High Pressure side closed 5 Turn on the vacuum pump to evacuate the system...

Страница 30: ...d valve high pressure valve and open the valve by turning the wrench in a 1 4 counter clockwise turn Listen for gas to exit the system then close the valve after 5 seconds 2 Watch the pressure gauge f...

Страница 31: ...4 During test run Check for electrical leakage During the test run use an electroprobe and multimeter to perform a comprehensive electrical leakage test If electrical leakage is detected turn off the...

Страница 32: ...roperly insulated Unit performs COOL function properly Unit performs HEAT function properly Indoor unit louvres rotate properly Indoor unit responds to remote controller Double check pipe connections...

Страница 33: ...ram Outdoor unit ODU model ODU printed circuit board KSI06 17122000048121 KSI09 KSI12 KSI18 17122000048064 KSI24 KSI28 Indoor unit abbreviations Abbreviation Paraphrase Y G Yellow green conductor ION...

Страница 34: ...te switch CN1 CN3 CN4 Display board Room temperature sensor Optional Wire controller Optional Wi Fi controller Optional 4 5 CN14 Room temperature sensor Pipe temperature sensor Switch board CN15 CN29...

Страница 35: ...nback L out L in CN2 CN11 CN16 N S CN43 CN8 CN9 2 2 Plasma UVC Micro switch Room temperature sensor Pipe temperature sensor Optional Optional Wi fi controller Wire controller CN10A CN10 8 4 Optional D...

Страница 36: ...6 DC Fan Optional Electronic expansion valve optional CN25 2 3 4 5 Capacitor CN15 White Pan heater Y G Optional 4 5 AC fan Optional CN17 Red Crankcase heater Optional Y G Power supply Indoor unit Fast...

Страница 37: ...ional 4 way Blue CN60 Optional Red CN16 White CN19 Optional Optional Optional Crankcase heater Pan heater Optional Y G CN5 Optional 2 3 4 5 AC fan Yellow white Capacitor CN18 Electronic expansion valv...

Страница 38: ...38 Kaden Installation Manual Outdoor unit printed circuit board diagram 17122000044714 17122000048121 17122000046453 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 39: ...nnect to 4 way valve 208 230V AC when is ON 4 HEAT2 CN15 Connect to chassis heater 208 230V AC when is ON 5 AC FAN CN25 Connect to AC fan 6 PMV CN31 Connect to electric expansion valve 7 TESTPORT CN6...

Страница 40: ...stallation Manual Outdoor unit printed circuit board diagram 17122000044714 17122000048121 17122000046453 E1 E2 C7 CN19 C12 AC AC L INCN8 Earth N INCN7 CN14 L601 R109 IPM501 C515 1 2 3 4 5 6 7 8 9 10...

Страница 41: ...HEAT2 CN19 Connect to chassis heater 208 230V AC when is ON 6 TP T4 T3 CN17 Connect to pipe temp sensor T3 ambient temp sensor T4 exhaust temp sensor TP 7 PMV CN18 Connect to electric expansion valve...

Страница 42: ...en circuit or has short circuited TS05 ODU 5 times EC 56 Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited for free match indoor units TS05 ODU 6 times EH 60 Indo...

Страница 43: ...ebsite Please check for the latest version 1s 0 4s 1 2s 0 4s 1s 0 4s 1 2s 0 4s For other errors The display board may show a garbled code or a code undefined by the service manual Ensure that this cod...

Страница 44: ...kadenair com au...

Отзывы: