KACO
blue-
planet
3.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
4.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
5.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
6.5 TL3
M2 WM
OD IIG0
KACO
blue-
planet
7.5 TL3
M2 WM
OD IIG0
KACO
blue-
planet
8.6 TL3
M2 WM
OD IIG0 -
3TL301
KACO
blue-
planet
9.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
10.0 TL3
M2 WM
OD IIG0 -
3TL301
Rated current
3x 4.20 A
[@415V];
3x 4.35 A
[@400V];
3x 4.60 A
[@380V]
3x 5.60 A
[@415V];
3x 5.80 A
[@400V];
3x 6.10 A
[@380V]
3x 7.00 A
[@415V];
3x 7.25 A
[@400V];
3x 7.60 A
[@380V]
3x 9.10 A
[@415V];
3x 9.50 A
[@400V];
3x 9.90 A
[@380V]
3x 10.50
A
[@415V];
3x 10.90
A
[@400V];
3x 11.40
A
[@380V]
3x 12.00
A
[@415V];
3x 12.50
A
[@400V];
3x 13.10
A
[@380V]
3 x 12.60
A
[@415V];
3 x 13.00
A
[@400V];
3 x 13.70
A
[@380V]
3x 14.95
A
[@415V];
3x 14.50
A
[@400V];
3x 15.20
A
[@380V]
Max. continuous current
3 x 4.8 A 3 x 6.4 A 3 x 8.0 A 3 x 10.5 A 3 x 12.0 A 3 x 13.2 A 3 x 14.0 A 3 x 15.5 A
Contribution to peak short-circuit
current ip
34.96 A
35 A
41 A
35 A
41 A
Initial short-circuit alternating
current (Ik" first single period ef-
fective value)
16.5 A
18.9 A
16.5 A
18.9 A
Short circuit current continuous
[ms] (max output fault current)
1,3 A
Inrush current
1.033 A [RMS (20ms)]
Rated frequency
50/60 Hz
Frequency range
45 - 65 Hz
Reactive power
0 - 95% Snom
cos phi
1 - 0.3 ind/cap
Number of feed-in phases
3
Distortion factor (THD)
0.36 %
0.32 %
0.31 %
0.29 %
3.85 %
0.27 %
Max. voltage range (up to 100 s)
287.5 V / 500 V
AC overvoltage protection
no
4.2
General Data
KACO
blue-
planet
3.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
4.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
5.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
6.5 TL3
M2 WM
OD IIG0
KACO
blue-
planet
7.5 TL3
M2 WM
OD IIG0
KACO
blue-
planet
8.6 TL3
M2 WM
OD IIG0 -
3TL301
KACO
blue-
planet
9.0 TL3
M2 WM
OD IIG0
KACO
blue-
planet
10.0 TL3
M2 WM
OD IIG0 -
3TL301
General electrical data
Max. efficiency
98.1 %
98.2 %
98.3 %
98.5 %
European efficiency
96.6 %
97.1 %
97.4 %
97.6 %
97.7 %
97.9 %
98.3 %
Self consumption: Standby
3 W
Feed-in from
20 W
Transformer unit
no
Protection class / over voltage
category
III / III
Grid monitoring
Country-specific
Distribution system
TN-C-System, TN-C-S-System, TN-S-System, TT-System
KACO blueplanet 3.0 TL3 KACO blueplanet 4.0 TL3 KACO blueplanet 5.0 TL3 KACO blueplanet 6.5 TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6 TL3 KACO blueplanet 9.0 TL3 KACO blueplanet 10.0 TL3
Page 11