9
H.
USING THE PASSAGE FUNCTION
H-1
Enter the user access code, followed by the “F” button.
H-2
Rotate the outside lever repeatedly. The latch should retract each time.
You are now in the passage mode.
NOTE
: To disable the passage function, depress the “F” button, followed by
the “C” button. The unit should now be locked.
I. REMOVING THE PASSAGE FUNCTION
If the passage function is not needed it can be easily removed.
I-1
Remove the 4 red screws located on the back of the outside unit assembly.
Pull the tumbler cover plate off (along with the springs) and set aside.
I-2
Depress the “C” button and hold depressed.
I-3
With the “C” still depressed, use the tweezers provided and remove the “F”
tumbler.
I-4
This tumbler hole can be left empty or replaced with a blue (uncoded)
tumbler.
I-5
Reinstall the tumbler cover plate and springs, using the 4 red screws
removed earlier.