3- Schematic Diagram
SCHEMATIC DIAGRAM
SR RFID READER AND
REMOTE CONTROL UNIT (RCU)
ELECTRIFIED
LOCKING DEVICE
ELECTRIFIED
LOCKING DEVICE
POWER SUPPLY
12 - 24 VOLTS
CONTROLLER ENCLOSURE
DOUBLE GANG BOX
(LOW VOLTAGE)
USE NORMALLY OPEN FOR ELECTRIC STRIKES
USE NORMALLY CLOSED FOR ELECTRO MAGNETS
NORMALLY CLOSED (BLACK)
NORMALLY OPEN (BLUE)
COMMON (RED)
DRY CONTACT OUTPUT
POWER INPUT
AC OR DC
12 - 24 VOLTS
(15 METER MAXIMUM)
SHIELDED CABLE
3 x 22 AWG TWISTED PAIR
SR RFID READER
(BACK VIEW)
MODULE
INTERFACE
RCU PCB
-6V
+6V
TX+
TX-
RX+
RX-
RF PCB (OPTIONAL)
2
1
3
4
5
6
Power Leads
The SR RFID RCU requires 12-24 volts AC or DC input. Two wire leads (white insulation) are provided for supplying
power to the controller. Ensure that voltage going to the controller does not exceed 24 volts.
Any 110 VAC power supplies necessary for rectification shall be in separate rated enclosures.
Relay Leads
Three wire leads (red, black, and blue) are provided for switching power to the electrified locking device attached to
the gate, door, doorframe, etc.
• The red lead is common. It is always connected.
• The black lead is normally closed (NC). It is used for electric lock devices like electromagnets.
• The blue lead is normally open (NO). It is used for electric lock devices like electric strikes.
Regulatory Compliance:
This device complies with Part 15 of the FCC Rules,.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications of this product, not approved by manufacturer will void the user’s authority to operate the equipment.
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.”
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation
est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
FCC ID: SAPMESSENGEREM
IC: 7078A-A28990
Contains transmitter module with FCC # SAPMESSENGER2GHZ and IC # 7078A-A28780