Saflok SR

TM 

Series RFID Reader Installation Guide - PK3670_T_08_15

The SR RFID remote control unit (RCU) controls access to electric strikes, electric exit devices, electromagnetic locks, and parking gates. Positioning the keycard 

over the reader will momentarily switch power to the electrified locking device.

Pre-installation Requirement

Be sure to investigate the switching current and voltages required by the electric access control hardware. The SR RFID RCU is 

equipped with a relay that can be configured either “normally open” or “normally closed,” to function properly with the hardware 

application. The relay is rated for 5 amps at 250 VAC or 5 amps at 30 VDC. Review your local fire and electrical codes before 

installing this product.

Power: (Not Supplied)

A Low voltage power source of 12 to 24 volts with a minimum current of 125 mA AC or DC is required but not included with the 

RCU.  

*Important*

 (DO NOT EXCEED 24 VOLTS)

Mounting Considerations: ?

Reader position (acordance with ADA requirements?)
Controller position (on the locked side of the entry. Convieient location for wiring. Secure location from vandalizsm?)
Wire specification / routing

RCU electrical configuration:

The RCU is equipped with a Dry Contact Relay that can be configured either Normally Open (NO) or Normally Closed (NC). 
The relay is rated for five Amps at 250VAC or 5 AMPS at 30VDC. Typically the NO set of contacts are used so that the ECU will 

work like the elevator call button to complete the circuit to call the elevator to the specific floor.  

*Important*

 Review your local Fire, Electrical and Building Codes before installing this product. Be sure to investigate the 

switching current and voltages present at the existing elevator buttons and determine if the RCU relay contact rating and 

configuration will be adequate.

The installer must be capable and knowledgeable of the electric access control system. There are many variations of electric 

access control systems and local codes; for this reason, the RCU must be installed by a qualified installer.

Messenger™ Option

For RCU units equipped with the Messenger transceiver module, the faceplate and electrical enclosure of the SR controller 

must be plastic to ensure optimum transmissions of the RF access communications to a nearby Messenger hub (for Messenger 

applications, SR RFID RCU faceplates are available in white, ivory, or dark brown plastic.)  If the RCU location has not been previ-

ously confirmed for connectivity to the Messenger network, consult the Messenger Site Survey Instructions. In some cases an 

additional hub may be required to ensure connectivity in new locations.

Programming

Program the RCU/ECU by using the propertys hand held programmer. Connect the USB probe to the USB port located on the 

serial interface board located in the controller box. 

1-  Pre-installation Requirements

Содержание Saflok SR Series

Страница 1: ...INSTALLATION GUIDE Saflok SRTM Series RFID RCU ECU ...

Страница 2: ...his confidential information contained herein may result in legal action by Computerized Security Systems dba SAFLOK and its parent company Made in North America 2015 Kaba Lodging Systems All trademarks and registered trademarks are the property of their respective owners SR1 Reader and Controller Box Ideal for Surface mount or mounting on aluminum door frame SR2 Reader and Controller Box Intended...

Страница 3: ...ve Amps at 250VAC or 5 AMPS at 30VDC Typically the NO set of contacts are used so that the ECU will work like the elevator call button to complete the circuit to call the elevator to the specific floor Important Review your local Fire Electrical and Building Codes before installing this product Be sure to investigate the switching current and voltages present at the existing elevator buttons and d...

Страница 4: ...4 Saflok SRTM Series RFID Reader Installation Guide PK3670_T_08_15 NONE Controller BOM ...

Страница 5: ...hing the SR1 back plate 2 Position the controller box on the opposite side of the wall within 15 meters of the reader 3 Run the appropriate wires to the controller enclosure and SR reader enclosure in accordance with the schematic diagram on the following page For connecting the reader to the controller 3 twisted pair x 22 AWG CMP cable is recommended Belden 6542FE or equivalent Ensure compliance ...

Страница 6: ...r electric lock devices like electromagnets The blue lead is normally open NO It is used for electric lock devices like electric strikes Regulatory Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may ...

Страница 7: ...Services Support Saflok 1 800 999 6213 1 248 837 3700 General Information www kabalodging com Online Consumable Orders www saflokstore com To access all of our easy steps please visit our Support Website www kabalodgingsupport com ...

Отзывы: