Testing Lock Functionality

Pass a Construction key over the Quantum RFID reader. The green light will flash for five seconds.  
Be sure that the green light flashes for five seconds while the exterior lever remains operable. If the  
green light does not flash, refer to the table below.

Lock Communication 

 Electronic Function Description

Red and green LEDs flash 

 

Time and date not set, use the Hand held and Quantum RFID  

nine times simultaneously  

                   

LPI probe to reset

or for 5 seconds 

  

Yellow LED flashes 12 times

 

 Dead bolt is thrown or switch cam is not properly aligned

Yellow LED flashes two times

 

 Keycard not allowed OR keycard cancelled by new keycard

Red and green LEDs flash

 

 Low battery (contact the SAFLOK service department)

alternately nine times

Yellow and red LEDs flash 

 

 Bad keycard read or corrupted data (may require new 

two times simultaneously

 

keycard) – Error logging to keycard.  Hold keycard in front of the  

 

lock reader longer. 

Red and yellow LED flashes two times

 

Keycard not read (Key reader may be damaged)

Содержание Saflok MT RFID

Страница 1: ...e sole use of the addressee s so named Any misuse of this confidential information contained herein may result in legal action by Computerized Security Systems dba SAFLOK and its parent company Optional Communication Modules I S Chassis Assembly I S Escutcheon 30320 H Color Assy Strike Buttons A29030 Color Screw Pack MT Universal 1 3 4 2 1 4 Mortise see Mortise Options table 51190 Color Outside Fr...

Страница 2: ... MT drill fixture position and clamp the fixture on the door Do NOT drill the four holes for the card reader as illustrated in Fig 1 below instead drill the hole shown in Fig 2 The fixture has two positioning posts that rest inside the mortise establishing the proper backset for the trim When the fixture is clamped its surfaces should be parallel with the door surfaces and door edges Not all holes...

Страница 3: ...pulled as the mortise is inserted into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightened Important DO NOT leave the mortise screws loose The screws must be fully tightened before the trim is installed If you must leave the mortise loose to install the t...

Страница 4: ...m edge of the rectangular hole with a piece of tape SAFLOK spacer plates will be required for doors less than 1 3 4 thick Be sure ribbon and power wire are completely pulled through the lock housing to ensure neither are pinched between the door and the lock chassis 3 Route the ribbon cable and power wire through the rectangular hole in the inside trim This hole is located above printed circuit bo...

Страница 5: ...tises or at the bottom 6 00 position for standard mortises see Fig 4 Position dead bolt spindle assembly into cam assembly The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy except when emergency keycards are used Important As...

Страница 6: ...erminal The programming port is located in the bottom of the outside lock trim Test the functioning of the lock as discussed in the following section and in the programming manual before closing the door When the construction key is used the green and red LEDs will blink together indicating that the lock s time and date are not set 15 For locks installed in exterior applications After programming ...

Страница 7: ...me and date not set use the Hand held and Quantum RFID nine times simultaneously LPI probe to reset or for 5 seconds Yellow LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned Yellow LED flashes two times Keycard not allowed OR keycard cancelled by new keycard Red and green LEDs flash Low battery contact the SAFLOK service department alternately nine times Yellow and red...

Страница 8: ...ons of the properties key design Door function Door closes and latches with little or no interference Dead bolt extends fully through the strike plate without interference door closed Spacing between door edge and inside door jamb does not exceed 3 16 door closed Note If bumpers or other seals are added after strike plate installation and causes alignment and latch problems it is the property s re...

Отзывы: