11
Reset Lock to Factory Mode (Hard Reset)
1.
Remove the lock back cover.
2.
Press and hold the small “Reset Switch” (SW2) on the bottom right hand
corner of the lock controller board with a non-metal tool.
3.
Depress the outside lever as you would to power the lock. Repeat this
action until you get two green flashes accompanied by beeps.
The lock settings are returned to the Factory Mode settings. All users are
deleted and the Master User PIN is reset to the Default Factory Master User
PIN of “12345678”. The lock is fully reset to Factory Mode.
Establish Communications Between Lock & M-Unit* (Handheld PDA)
* This operation is normally used in conjunction with uploading and
downloading data to and from the lock. See the
Getting Started Guide
or the
Reference Manual
for detailed information on these operations.
1.
Power lock.
2.
If PIN is required, enter Master User PIN, Manager User PIN, or M-Unit
User PIN.
3.
If PROX Card is required, present PROX Card.
4.
Press
:
followed by
900
.