60 II_PAXOS_V001_20161007_EN
PAXOS advance Series
Addressing/functional check of the system
Installation Instructions
Functional check
1.
Close the boltwork if the container door is open. All of the door locks should automatically
close one after another. The following displays appear.
The system status “Secured” is displayed.
If the locks do not close, check whether the door bolt contacts are closed. If the door bolt
contacts are not closed, set them so that they are securely closed when the boltwork is closed.
2.
Check the play of the lock bolt(s). The play of the lock is correct, if the lock bolt can be
moved slightly back and forth in the closed position.
Note!
If the lock bolt cannot be moved or can only be moved in one direction, the lock has little play
which can cause problems during operation. In this case, the carrier mechanism or the lock
must be readjusted.
3.
Press any key or the dial knob to activate the input unit. The system status is displayed.
4.
Press the <ENTER> key or the dial knob and the first menu option of the operator menu is
displayed (“Open”). Then press the <ENTER> key or dial knob again.
5.
The code input to open door lock 1 is displayed. Enter the opening code “10203040” (factory
code ; or “0010203040“ with ID+PIN mode) via the keypad or dial knob. Confirm the code
with the <ENTER> key or by pressing the dial knob.
The lock is opened.
6.
If there are more door locks, the code input for the next door lock is automatically displayed.
Repeat step 5 for all of the other door locks.
7.
Once all of the door locks are open, you will be prompted to open the boltwork. Open the
boltwork and the message “Unlocked” is displayed.