48 II_PAXOS_V001_20161007_EN
PAXOS advance Series
Installation
Installation Instructions
1
Connection of the uninterruptible power supply
The uninterruptible power supply of the hazard alert/intrusion detection system or an
uninterruptible power supply unit must be connected to terminals 14 and 15 of the IP-Box
in accordance with the diagram.
Batteries or a rechargeable battery pack do not necessarily need to be inserted in the battery
compartment of the input unit when Paxos advance
is operated with an uninterruptible power
supply.
2
Connection of the locking status signal
The locking status signal is required to inform the hazard alert/intrusion detection system
whether the locks and door bolt contacts are open or closed. Output 2 of the IP-Box
(terminals 9 and 10) must be connected to the hazard alert/intrusion detection system in
accordance with the diagram.
Functionality of output 2: Locking status
Contact open:
All of the locks and door bolts are open (unlocked)
Contact closed:
All of the locks and door bolts are closed (locked)
3
Connection of the remote locking signal
The remote locking signal is required for the hazard alert/intrusion detection system to lock
or unlock the locking system. The isolated remote lock contact of the hazard alert/intrusion
detection system must be connected with a tamper-monitoring switch on input 1 of the
IP-Box (terminals 1 and 2) in accordance with the diagram.
Functionality of input 1: Remote lock
Contact open:
Remote lock activated
Contact closed:
Remote lock deactivated
Содержание PAXOS advance Series