12
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter the code
008#VV# (where VV is a scale of volume from
00 to 03; 00 = off; 01 = Low; 02 = Normal; 03 = High).
3.
Example of Complete Entry:
008#02#.
4.
Enter another
# to indicate the end of programming.
5.
The lock will now sound the buzzer at the desired volume
Normal, until you change it.
Users - General Information
1.
Master and Manager Codes can do two different things:
•
Open the door by entering the Access Code without
# signs.
•
Put the lock into Pushbutton Programming Mode by entering
# before and after their Access Code.
2.
Each user (Manager User, Service User or Access User) occupies
one of the available 100 locations in the user table.
3.
By default, user 000 is the Master User.
4.
The M-Unit User is outside of the user table (only applicable
with E-Plex 5000 PC software use).
5.
Users have a 15-second period to enter the entire key sequence,
and 5 seconds between pressing each pushbutton number. If
they pause longer than 5 seconds between each pushbutton
pressed, or exceed the 15-second period to enter the total
sequence, the lock:
• aborts the current programming sequence
• automatically exits the programming state
• sends the user a ‘Keypad Timeout’ feedback message
Note: Correct errors during a command sequence. If an invalid
entry occurs, recover from the mistake by entering the (*) key, which will
clear all entries made from the beginning of the current command
sequence, and will reset the 15-second time limit for entering the code.
In this case, you still have 15 seconds from the first number entered to
enter the whole code.