![background image](http://html.mh-extra.com/html/kaba/access-manager-92-30/access-manager-92-30_technical-manual_649058039.webp)
Technical Manual
Installation
39
04045376 - 05/2016
Kaba access manager 92 30
5.2.2
Access control with reader via RS-485
Example:
•
Access control with biometric reader via RS-485
•
External power supply of the biometric reader
•
External power supply of the access manager
1
Kaba access manager 92 30
2
Host computer
3
Biometric reader
4
Door opener key
5
Door opener
6
Door frame contact
7
External 24 V DC power supply for the access manager
8
External 24 V DC power supply for the biometric reader
Installation lines
A
Data line to the reader (RS-485)
B
Line to the door contact, the door opener key, and the door opener
C
Ethernet network cable
D
Power supply line Access manager
E
Power supply line Biometric reader