background image

RAC Model 3.5 with KIM Swipe Reader

8

4.2 Hotel ID Reinitialization

To reinitialize the Hotel ID code: 

1. Set the switches in switch bank S2 to CFG #16.

2. Swipe a new initialization keycard through the swipe reader. The red and green LEDs on the KIM

Swipe Reader will flash in sequence -red once, green twice. 

3. Wait for the LEDs to flash as described, then set the DIP switch positions back to the chosen access

delay setting.

4.3 Battery Replacement (KABA ILCO Part #120-507947)

Warning: The power supply uses high voltage; only a qualified person 
should replace the battery.

1.  Prior to replacing the battery, write down the color and location of each wire and the orientation of the

batteries.

2.  Disconnect all wires.

3.  While holding the battery in place, remove both screws holding the retaining bracket. 

4.  Replace battery with the same type gelled lead acid cell 12 V, 7.0 AH (Ampere-hours). Put the new

battery in the same position, install the retaining bracket and reconnect all the wires. Dispose of the
old battery according to local regulations.

Note:  For preventative maintenance, back-up batteries should be replaced every 2 to 

3 years, and tested every 6 months by removing main AC power.

4.4 Power Failure

In the event of an electrical failure, the system will revert to standby status for a period of 4 hours 

(if the

optional battery is installed)

. If the electrical power is restored within three days, the system will recover

automatically and should require no additional programming. Verify the status of the LED D18 on the con-
troller PCB in question. If the LED is OFF, swipe an initialization or start-up card through the reader and
reset the lock time to ensure that the controller will function properly. See Table 3 on page 5 for Status LED
definitions.

4.5 Loading Recommendations

Caution: Do not exceed the load limitations of the control panel.

The maximum recommended load for all output relays in the card reader control panel is 1 Amp at 30 VDC.
The tamper switch rating is 1 Amp for 115VAC and 0.5 Amp for 230VAC applications.

4.6 System Deactivation

In order to deactivate the card reader control panel, disconnect both terminals from the standby battery,
then disconnect the AC power either by removing the quick disconnect terminal located at TB1 of the power
supply or by shutting off the main breaker switch for the control panel.

Содержание 3.5

Страница 1: ...INSTALLATION GUIDE Remote Access Controller Model 3 5 with KIM Swipe Reader Solitaire 710 II 710 System 700 Generation E 760 PK2918 ...

Страница 2: ...ccessories 9 Drilling Templates 11 Disclaimer Please read and follow all directions carefully These instructions are designed for use by maintenance professionals or lock installers who are familiar with common safety practices and competent to perform the steps described Kaba Ilco is not responsible for damage or malfunction due to incorrect installation however arising Carefully inspect windows ...

Страница 3: ...ontrol panel should be securely screwed to the wall using the four mounting holes If possible the control panel should be mounted at a workable height with clearance to open the door com pletely Notes Access to control panel is restricted to service personnel only A certified electrician must connect the AC power to the Control Panel in accordance with applicable local standards Kaba Ilco is not r...

Страница 4: ...e cable shield to the chassis ground connection at terminal TB6 on the Power Supply C 11 Install the diode across the terminals of the electromagnetic lock E or using the butt connectors provided in the Installation Kit install the diode across the two wires of the electric strike G Do not reverse diode polarity Note This step is not necessary if installing an HES 7000 Series electric strike or Ru...

Страница 5: ...emplate for the Satin Chrome KIM Swipe Reader located at the end of this booklet mark the holes for the cable and screws 2 Wearing safety glasses drill the holes in the wall Enlarge the upper part of the cable hole 3 Tap the plugs into the wall then tighten the screws fully Undo the screws one turn leaving a small gap between the screw head and the wall 4 Fish the cable to the control panel and ma...

Страница 6: ...tromagnetic Lock Electric Strike Note 1 Due to Hanchett Entry Systems HES modifying their 7000 series electric strikes and Rutherford Controls modifying their 83xx series electromagnetic locks to include an on board diode it is no longer necessary to install the diode from the installation kit ...

Страница 7: ...eir 7000 series electric strikes and Rutherford Controls modifying their 83xx series electromagnetic locks to include an on board diode it is no longer necessary to install the diode from the installation kit Dual Reader Access Controller Assembly Electromagnetic Lock Electric Strike ...

Страница 8: ...ccess Delay DIP Switch Settings S2 CFG 4 3 2 1 SEC 1 ON ON ON ON 8 2 ON ON ON OFF 1 3 ON ON OFF ON 3 4 ON ON OFF OFF 5 5 ON OFF ON ON 10 6 ON OFF ON OFF 15 7 ON OFF OFF ON 20 8 ON OFF OFF OFF 25 9 OFF ON ON ON 30 10 OFF ON ON OFF 35 11 OFF ON OFF ON 40 12 OFF ON OFF OFF 50 13 OFF OFF ON ON 60 14 OFF OFF ON OFF 90 15 OFF OFF OFF ON 120 16 OFF OFF OFF OFF REINIT Example of S2 Settings Delay times ca...

Страница 9: ...nnector programming port P1 on the controller PCB in the control panel Refer to Figure 1 or Figure 2 for the positions of the J1 and P1 connectors Refer to Figure 4 or Figure 5 below for an illustration 2 For step by step programming instructions refer to chapter 5 of the Kaba Ilco Lodging Access Control System Reference Manual version 6 5 or higher Note When programming the RAC you do not swipe t...

Страница 10: ...nce back up batteries should be replaced every 2 to 3 years and tested every 6 months by removing main AC power 4 4 Power Failure In the event of an electrical failure the system will revert to standby status for a period of 4 hours if the optional battery is installed If the electrical power is restored within three days the system will recover automatically and should require no additional progr...

Страница 11: ...ng their 7000 series electric strikes and Rutherford Controls modifying their 83xx series electro magnetic locks to include an on board diode it is no longer necessary to install the diode from the installation kit NOTE 1 Due to Hanchett Entry Systems HES modifying their 7000 series electric strikes and Rutherford Controls modifying their 83xx series electro magnetic locks to include an on board d...

Страница 12: ...with Timer NOTE 1 Due to Hanchett Entry Systems HES and Rutherford Controls modifying their electro magnetic locks to include an on board diode it is no longer necessary to install the diode from the installation kit For electric strikes it is still necessary to install the diode from the installation kit ...

Страница 13: ...Installation Guide 11 Notes Drilling Templates for KIM Swipe Readers SATIN CHROME BLACK Drill 0 25 hole for cable 6 x 0 5 12 7 mm screw x4 4 x 0 125 3 175 mm hole 1 3 33 mm Back Panel of Reader ...

Страница 14: ...ntréal QC H4P 2G7 Technical Support 1 800 906 4526 Customer Service T 1 877 468 3555 F 514 735 6589 General Information www kabalodging com Online Consumable Orders www keycard com To access all of our easy steps please visit our Support Website http connect kabalodging com ...

Отзывы: