14  Partial commissioning / Complete commissioning 

 
Once the lock has been mounted, partial commissioning (only by means of PC software) or complete commissioning (by means 
of PC software or via the input unit) can take place. 
In partial commissioning, the locking system is configured (e.g., setting of silent alarm, double code, code preassignment),  but 
these settings will not become active until the lock is commissioned completely by activating the master code. This function is 
helpful  in  particular  for  simplifying  operation  during  mounting  to  the  secure  storage  unit  and  prior  to  delivery  to  the  custo mer. 
This  means  that  the  lock  will  initially  still  open  by  entering  the  assembler  code.  In  contrast  to  partial  commissioning,  after 
complete  commissioning,  all  programmed  codes  and  functions  will  be  available,  whereas  the  assembler  code  is  disabled.  
For complete commissioning, two methods are available: 
- Partial commissioning by means of PC software, followed by complete commissioning by means of the input unit 
- Commissioning by means of the input unit 
The procedure for partial commissioning can be found in the operating  instructions of the PC software. How to proceed further 
in complete commissioning can be found in the operating instructions of the lock, chapter 8.  
 

Locks that have been partly commissioned should be completely commissioned prior to handing them over to the end 
customer.  Both  in  partial  and  complete  commissioning,  the  customer  must  be  notified  of  all  programmed  codes  and 
functions!  The  appropriate  data  of  the  presettings  made  (codes,  functions)  should  be  mentioned  for  the  user  in  the 
instructions  of  the  secure  storage  unit  or  in  additional  documents.  In  addition  to  that,  the  set  master  code  can  be 
documented in the operating instructions of the lock. For more information on this, please refer to the area highlighted 
in gray in chapter 1, page 4, "Master code set by the distributor or manufacturer of the safe" and chapter 15. 

 
 

15  Functional test 

 
The function of the lock must be tested according to chapter 8.1 ff. of the operating instructions of the lock with the door opened. 
The mechanical opening by means of the double-bit key must also be tested (see operating instructions lock chapter 11). 
 

As long as the assembler code is used for opening (master not yet enabled), there is no guard time for incorrect code 
inputs and no take-off contact signal message either. After the master has been enabled, the removal of the top part of 
the  input  unit  is  detected  by  the  lock.  Each  opening  will  result  in  suitable  signaling.  How  to  reset  the  lift-off  contact 
message can be found in the operating instructions of the lock in chapter 9.6. 

 
 

16  Permanent power supply 

 
Two batteries of type AAA are available in the input unit for power supply of the lock. 
If necessary, along with the battery power supply the lock can also be supplied permanently with voltage. The technical data  of 
permanent power supply can be found in chapter 10. 
 

Even with permanent power supply, the batteries must still be inserted into the input unit because otherwise the lock 
can  no  longer  be  opened  by  means  of  the  code  input  in  case  of  power  failure  or  a  defect  in  the  permanent  power 
supply.  A  failure  of  the  permanent  power  supply  and  a  low  battery  capacity  will  trigger  the  undervoltage  display  
(see operating instructions chapter 13.1). The batteries and the permanent power supply should be checked as soon 
as possible in this case. 

 

 

Содержание Combi B 30 Series

Страница 1: ...metal input unit Mounting instructions EN CLAVIS Deutschland GmbH Schillerstraße 47 51 34117 Kassel Telefon 49 0 561 988 499 0 Fax 49 0 561 988 499 99 E Mail info tresore eu Internet www tresore eu www tresorschloss de ...

Страница 2: ...t 30 12 3 Drive shaft 31 13 Mounting the locking system 32 13 1 Mounting the lock 32 13 2 Mounting the drive shaft 32 13 3 Mounting the input unit 33 13 3 1 Dismounting the input unit 33 13 3 2 Adjusting the keypad sub assembly 34 13 3 3 Mounting the connecting cable 36 13 3 4 Fastening the base part 37 13 3 5 Inserting the batteries 37 13 3 6 Mounting the input unit top part 38 13 4 Checking perf...

Страница 3: ...to the upper part of the keypad frame 34 Figure 40 After removing the top holder turn around the fitting 34 Figure 41 Carefully pull out the keypad sub assembly toward the back 34 Figure 42 Mounting the keypad sub assembly 35 Figure 43 Connecting cable from the input unit to the lock 36 Figure 44 Detail of the socket 36 Figure 45 Inserting the top part 38 Figure 46 Moving the top part 38 Figure 47...

Страница 4: ...k the locking system must be de energized during wiring i e the batteries in the input unit and power supply units must be removed Otherwise the lock electronics may become damaged The locking system is suitable for installation in secure storage units made of steel provided with or devoid of padding materials Installation in units made of other materials such as plastic is not allowed The proper ...

Страница 5: ...ion switch Change over contact 30V DC 0 1 A Pin1 Common Pin2 Normally Closed Pin3 Normally Open Silent alarm 3 Max 24 V DC 25 mA Pin6 Collector Pin7 Emitter Lock Input signal Only configurable via the Combi B 30 configuration software only one function each possible stan dard disabled Remote control disable 12V DC 10 Pin4 12V Pin5 GND Omission alarm min actuation time 500 ms opening must take plac...

Страница 6: ...o lock 6 pin connector I O mini USB connector Data interface to PC Connects the input unit to the PC by means of the Kaba Mauer CB30 PC cable in order to read the audit or configure the lock As pre assigned internally Notice Special interface use only original Kaba Mauer CB30 PC cable Table 8 Overview input unit connections Figure 26 Input unit connection I O mini USB connector Connecting cable to...

Страница 7: ...crew for arresting the upper part of the input unit F H 2 9 x 6 5 mm 7 Rotary handle 8 Upper part of the input unit 9 Mounting screws for base part M4 x 6 0 mm 10 Cable binder 11 Base part of the input unit 12 Connecting cable input unit lock Not included in the scope of delivery 13 Mounting screws for the lock recommended M6 x 30 mm or x 30 mm see chapter 13 1 14 2 batteries 1 5 volts type AAA LR...

Страница 8: ...ons that are outside the data shown in Figure 28 must be coordinated separately with certifiers test institutes The position of the key hole the dimensions and the resulting required space for the installation of the lock can be seen from Figure 28 The following figure refers to the installation position Bolt on the left For other installation positions the figure must be rotated according to Tabl...

Страница 9: ...secure storage unit it is recommended inserting the Kaba Mauer key guide see Figure 29 or the Kaba Mauer key carrier guide see Figure 30 In these cases taking into consideration DIN 2768 mH the key in the secure storage unit must be manufactured with the corresponding dimensions Figure 29 Key guide 86101 Figure 30 Key carrier guide R 4 R4 O 8 4 2 4 2 5 9 5 9 25 5 1 2 75 ...

Страница 10: ...Table 11 if necessary In addition to that another cutout is required in the cabinet door used as cable passage for the connecting cable 12 between lock 1 and input unit 8 11 The size of the cable passage hole must not be more than 100 mm 2 e g a hole max 11 25 in diameter and the hole must be positioned within the area of Figures 32 Installation position Figure Rotation 32 Not required 32 90 clock...

Страница 11: ...ween the lock mounting plane and the input unit mounting plane 20 mm immersion depth into the input unit 26 5 mm immersion depth into the lock tolerance 0 2 mm see Figure 32 Shorten the drive shaft 2 only on the side not drilled see Figure 33 To shorten it the drive shaft 2 must be removed from the lock since otherwise there will be a risk of damaging the lock Figure 32 Required length of the driv...

Страница 12: ...t 30 mm is recommended For the fastening screws a minimum strength class of 4 8 and a maximum strength class of 8 8 must be observed The screws must be secured either with a spring washer toothed lock washer or serrated lock washer or by means of a screw locking adhesive The tightening torque must be between 5 and 6 Nm After mounting and adjusting the lock on the storage unit door you must ensure ...

Страница 13: ...len wrench Insert Allen wrench 5 as shown in the figure into the small hole in the input unit 8 11 as far as it will go Figure 36 Pulling off the rotary handle Keep the Allen wrench 5 pressed while pulling off the rotary handle 7 toward the front as shown Figure 37 Loosening the screw Move the top part of the input unit 8 in the direction of the arrow until it makes contact with the base part 11 F...

Страница 14: ...b assembly from its top holders Next remove the keypad unit carefully from its bottom holders see Figures 42 and 43 and then take it out of the top part of the operating unit 8 toward the back if possible without tilting or deforming the holding clamps Remark Do not mount the keypad sub assembly in other top parts because the top parts of the input unit 8 is labled with the product data label with...

Страница 15: ...ry handle on the left keypad on the right Not required Rotary handle at the top keypad at the bottom 90 counterclockwise Rotary handle at the bottom keypad at the top 90 clockwise Rotary handle on the right keypad on the left 180 Table 12 Installation position of the input unit notes for Figures15 to18 Figure 42 Mounting the keypad sub assembly ...

Страница 16: ...art 11 via the green miniplug JST 5 pin see Figure 43 step I Notice In doing so ensure correct alignment of the plug to the socket Under no circumstances must the plug be inserted twisted and with force since the socket shape clearly determines the alignment of the plug see Figure 44 Figure 44 Now fix the connecting cable 12 as shown in Figure 43 step II using the cable binder 10 as traction relie...

Страница 17: ...t make sure that it is laid below the base part up to the passage hole in the cabinet Notice The turnament to fix the base part 11 must not exceed 1 3 Nm Notice To fasten the base part only the enclosed screws 9 whose screw head size match exactly the input unit should be used Should you use any other screws you have to make sure that the screw head height does not exceed 2 6 mm since otherwise th...

Страница 18: ...8 Mounting the rotary handle Check the O ring 3 seat once again 5 8 mm from the front edge of the shaft Then insert the rotary handle 7 and lock it into place In doing so make sure that in the locked state of the lock 1 the KABA logo or the opening indication 15 small depression is horizontal Should the rotary handle 7 not lock into place do not apply force but check the length of the shaft the co...

Страница 19: ...entioned for the user in the instructions of the secure storage unit or in additional documents In addition to that the set master code can be documented in the operating instructions of the lock For more information on this please refer to the area highlighted in gray in chapter 1 page 4 Master code set by the distributor or manufacturer of the safe and chapter 15 15 Functional test The function ...

Страница 20: ...40 Mounting instructions 82132 3xxx CB 30 CLAVIS Deutschland GmbH Schillerstraße 47 51 34117 Kassel Telefon 49 0 561 988 499 0 Fax 49 0 561 988 499 99 E Mail info tresore eu Internet www tresore eu www tresorschloss de Kundendienst ...

Отзывы: