3.1 Opening with master code
1) Press
ON and keep pressed
2) Enter valid 8-digit master code
1 x
3) Within 4 seconds turn bar handle clockwise until stop position reached
3.2 Opening with user code
1) Press
ON
2) Enter valid 4-digit user code
1 x
3) Within 4 seconds turn bar handle clockwise until stop position reached
3.3 Opening after 3 or more incorrect code entries
penalty time
After 3 incorrect entries the lock goes into a one minute blocked status. The period in which
the lock is blocked is extended to 2, 4, 8 and a maximum of 1 minutes every time an incorrect
code is entered. During this period the red LED flashes every second and it is not possible to
enter any further codes. When the blocked period is over,
ON may be pressed again at any
time.
1) Press
ON after the red LED stopped flashing
2) Enter 4-digit user code or 8-digit master code
1 x
3.4 Alteration of the master code
1) Open lock with valid 8-digit master code (see 3.1)
2) Press
ON and keep pressed
3) Press
P
4) Enter valid 8-digit master code
5) Don’t keep
ON pressed
) Enter new 8-digit master code
/ 2 x
7) Enter new 8-digit master code again
1 x
If the new master code as per 7) was incorrectly confirmed, the signal
3 x
appears. Re-
peat the sequence.